FIALOVÁ, Kateřina, Jana KOLÁŘOVÁ, Jiří SEKORA, Milan TANNENBERG, Marie NOVÁKOVÁ a Ivo PROVAZNÍK. Electrophysiological Effects of Voltage Sensitive Dye di-4-ANNEPS in Rabbit and Guinea Pig Isolated Heart. Analysis of Biomedical Signals and Images. Brno: Vutium Press, 2010, roč. 20, č. 1, s. 108-113. ISSN 1211-412X.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Electrophysiological Effects of Voltage Sensitive Dye di-4-ANNEPS in Rabbit and Guinea Pig Isolated Heart
Název česky Elektrofyziologické účinky napěťově citlivého barviva di-4-ANEPPS studované na modelu izolovaného srdce králíka a morčete
Autoři FIALOVÁ, Kateřina (203 Česká republika, garant, domácí), Jana KOLÁŘOVÁ (203 Česká republika), Jiří SEKORA (203 Česká republika), Milan TANNENBERG (203 Česká republika), Marie NOVÁKOVÁ (203 Česká republika, domácí) a Ivo PROVAZNÍK (203 Česká republika).
Vydání Analysis of Biomedical Signals and Images, Brno, Vutium Press, 2010, 1211-412X.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30105 Physiology
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
Kód RIV RIV/00216224:14110/10:00044669
Organizační jednotka Lékařská fakulta
UT WoS 000303723700017
Klíčová slova anglicky voltage sensitive dye; isolated heart
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: prof. MUDr. Marie Nováková, Ph.D., učo 1188. Změněno: 25. 1. 2011 10:43.
Anotace
Voltage-sensitive dye (VSD) di-4-ANEPPS is currently used in our laboratory for recording of monophasic action potentials (MAPs) in isolated hearts. In this study, its electrophysiological effects on rabbit and guinea pig myocardium were compared during staining with VSD and washout from it. Electrograms were recorded and heart rate changes and the types and frequency of arrhythmias were evaluated. Althought certain electrophysiological changes were present in the hearts of both species, these changes are mostly reversible, especially in rabbit hearts. Thus, rabbit myocardium can be considered a reliable model for electrophysiological studies, especially when generation and propagation of the impulse is studied. It may be concluded that rabbit isolated heart is more suitable model for electrophysiological studies in the isolated heart model than guinea pig heart.
Návaznosti
GA102/07/1473, projekt VaVNázev: Optické metody registrace elektrických potenciálů a koncentrace vápníku v srdci s laserovou stabilizací
Investor: Grantová agentura ČR, Optické metody registrace elektrických potenciálů a koncentrace vápníku v srdci s laserovou stabilizací
MSM0021622402, záměrNázev: Časná diagnostika a léčba kardiovaskulárních chorob
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Časná diagnostika a léčba kardiovaskulárních chorob
VytisknoutZobrazeno: 25. 4. 2024 18:10