ŘEMÍNEK, Roman and Zdeněk GLATZ. Study of Atypical Kinetic Behaviour of Cytochrome P450 2C9 Isoform with Diclofenac at Low Substrate Concentrations by Sweeping-MEKC Combination. Journal of Separation Science. Německo: WILEY-VCH Verlag GmbH & Co., vol. 33, No 20, p. 3201-3206. ISSN 1615-9306. 2010.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Study of Atypical Kinetic Behaviour of Cytochrome P450 2C9 Isoform with Diclofenac at Low Substrate Concentrations by Sweeping-MEKC Combination
Name in Czech Studium atypického kinetického chování cytochromu P450 2C9 s diclofenac při nízkých koncentracích substrátu pomocí Sweeping-MEKC
Authors ŘEMÍNEK, Roman (203 Czech Republic) and Zdeněk GLATZ (203 Czech Republic, guarantor).
Edition Journal of Separation Science, Německo, WILEY-VCH Verlag GmbH & Co. 2010, 1615-9306.
Other information
Original language English
Type of outcome Article in a journal
Field of Study 10600 1.6 Biological sciences
Country of publisher Germany
Confidentiality degree is not subject to a state or trade secret
Impact factor Impact factor: 2.631
RIV identification code RIV/00216224:14310/10:00044832
Organization unit Faculty of Science
UT WoS 000284181900013
Keywords (in Czech) Sweeping; Cytochrom P450; Diclofenac; Metabolismus léčiv.
Keywords in English Sweeping; Cytochrome P450; Diclofenac; Drug metabolism.
Tags International impact, Reviewed
Changed by Changed by: prof. RNDr. Zdeněk Glatz, CSc., učo 1865. Changed: 13/12/2010 08:16.
Abstract
In view of the fact that several studies have shown that diclofenac hydroxylation by cytochrome P450 2C9 deviated from Michaelis-Menten kinetics at low substrate concentrations, sweeping combined with MEKC was applied for the kinetic study of this pharmacologically important reaction. A 50 um fused silica capillary (56 cm effective length) was used to carry out all separations. 70 mM SDS in 20 mM phosphate 20 mM tetraborate buffer pH 8.6 was used as the background electrolyte. Injection was accomplished by the application of 50 mbar (5 kPa) pressure to the sample vial for 52 s. Separation was performed at 22 kV (positive polarity), with a capillary temperature of 25 C and detection at 200 nm. The higher sensitivity of the sweeping-MEKC combination compared to the simple MEKC method enabled this reaction to be fitted to a Hill kinetic model and confirmed the findings of other authors. A Michaelis constant of 2.91 uM, maximum reaction velocity of 9.16 nmol/min/nmol and Hill coefficient of 1.66 were found.
Abstract (in Czech)
Byla provedena studie atypického kinetického chování cytochromu P450 2C9 s diclofenac při nízkých koncentracích substratu pomocí Sweeping-MEKC
Links
GAP206/10/0057, research and development projectName: Miniaturizovaný systém pro "on-line" studie metabolismu léčiv založený na kapilární elektroforéze
Investor: Czech Science Foundation, Miniaturized on-line drug metabolism system based on capillary electrophoresis
LC06023, research and development projectName: Integrované bioanalytické technologie pro mikroanalýzy a diagnostiku s využitím LIF a hmotnostní spektrometrie
Investor: Ministry of Education, Youth and Sports of the CR
MSM0021622413, plan (intention)Name: Proteiny v metabolismu a při interakci organismů s prostředím
Investor: Ministry of Education, Youth and Sports of the CR, Proteins in metabolism and interaction of organisms with the environment
PrintDisplayed: 20/4/2024 04:30