Detailed Information on Publication Record
2010
Radiographic Assessment of Implant Failures of Titanium 3.5 LCP vs. 4.5 LCP Used for Flexible Bridging Osteosynthesis of Large Segmental Femoral Diaphyseal Defects in a Miniature Pig Model
NEČAS, Alois, Pavel PROKS, Lucie URBANOVÁ, Robert SRNEC, Ladislav STEHLÍK et. al.Basic information
Original name
Radiographic Assessment of Implant Failures of Titanium 3.5 LCP vs. 4.5 LCP Used for Flexible Bridging Osteosynthesis of Large Segmental Femoral Diaphyseal Defects in a Miniature Pig Model
Authors
NEČAS, Alois (203 Czech Republic, guarantor, belonging to the institution), Pavel PROKS (203 Czech Republic, belonging to the institution), Lucie URBANOVÁ (203 Czech Republic, belonging to the institution), Robert SRNEC (203 Czech Republic), Ladislav STEHLÍK (203 Czech Republic), Michal CRHA (203 Czech Republic, belonging to the institution), Petr RAUŠER (203 Czech Republic, belonging to the institution), Ladislav PLÁNKA (203 Czech Republic, belonging to the institution), Evžen AMLER (203 Czech Republic, belonging to the institution), Lucy VOJTOVÁ (203 Czech Republic, belonging to the institution) and Josef JANČÁŘ (203 Czech Republic, belonging to the institution)
Edition
Acta Veterinaria, Brno, VETERINARNI A FARMACEUTICKA UNIVERZITA B, 2010, 0001-7213
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
30211 Orthopaedics
Country of publisher
Czech Republic
Confidentiality degree
není předmětem státního či obchodního tajemství
Impact factor
Impact factor: 0.534
RIV identification code
RIV/00216224:14110/10:00047572
Organization unit
Faculty of Medicine
UT WoS
000287418300012
Keywords in English
Fracture fixation; bone healing; comminuted fracture; nonunion; ostectomy; buttress plate
Změněno: 17/3/2011 02:51, prof. MUDr. Ladislav Plánka, Ph.D.
V originále
Compared to the six-hole 3.5 mm LCP, the five-hole titanium 4.5 mm LCP is more suitable implant for flexible bridging osteosynthesis of a critically sized segmental defect of femoral diaphysis in the miniature pig. The results of this study will allow reducing implant failures in time-and cost-demanding transplantation experiments focused on bone healing. Compared to the six-hole 3.5 mm LCP, the five-hole titanium 4.5 mm LCP is more suitable implant for flexible bridging osteosynthesis of a critically sized segmental defect of femoral diaphysis in the miniature pig. The results of this study will allow reducing implant failures in time-and cost-demanding transplantation experiments focused on bone healing.
In Czech
Pětiděrová titanová 4,5 mm LCP se v porovnání s šestiděrovou 3,5 mm LCP jeví jako vhodnější implantát k provedení flexibilní pilířové osteosyntézy velkého segmentálního defektu diafýzy femuru u miniaturního prasete jako zvířecího experimentálního modelu. Výsledky této studie umožní omezit nežádoucí selhání implantátů při časově a finančně náročných transplantačních experimentech zaměřených na hojení kostí.