J 2010

Radiographic Assessment of Implant Failures of Titanium 3.5 LCP vs. 4.5 LCP Used for Flexible Bridging Osteosynthesis of Large Segmental Femoral Diaphyseal Defects in a Miniature Pig Model

NEČAS, Alois, Pavel PROKS, Lucie URBANOVÁ, Robert SRNEC, Ladislav STEHLÍK et. al.

Basic information

Original name

Radiographic Assessment of Implant Failures of Titanium 3.5 LCP vs. 4.5 LCP Used for Flexible Bridging Osteosynthesis of Large Segmental Femoral Diaphyseal Defects in a Miniature Pig Model

Authors

NEČAS, Alois (203 Czech Republic, guarantor, belonging to the institution), Pavel PROKS (203 Czech Republic, belonging to the institution), Lucie URBANOVÁ (203 Czech Republic, belonging to the institution), Robert SRNEC (203 Czech Republic), Ladislav STEHLÍK (203 Czech Republic), Michal CRHA (203 Czech Republic, belonging to the institution), Petr RAUŠER (203 Czech Republic, belonging to the institution), Ladislav PLÁNKA (203 Czech Republic, belonging to the institution), Evžen AMLER (203 Czech Republic, belonging to the institution), Lucy VOJTOVÁ (203 Czech Republic, belonging to the institution) and Josef JANČÁŘ (203 Czech Republic, belonging to the institution)

Edition

Acta Veterinaria, Brno, VETERINARNI A FARMACEUTICKA UNIVERZITA B, 2010, 0001-7213

Other information

Language

English

Type of outcome

Článek v odborném periodiku

Field of Study

30211 Orthopaedics

Country of publisher

Czech Republic

Confidentiality degree

není předmětem státního či obchodního tajemství

Impact factor

Impact factor: 0.534

RIV identification code

RIV/00216224:14110/10:00047572

Organization unit

Faculty of Medicine

UT WoS

000287418300012

Keywords in English

Fracture fixation; bone healing; comminuted fracture; nonunion; ostectomy; buttress plate
Změněno: 17/3/2011 02:51, prof. MUDr. Ladislav Plánka, Ph.D.

Abstract

V originále

Compared to the six-hole 3.5 mm LCP, the five-hole titanium 4.5 mm LCP is more suitable implant for flexible bridging osteosynthesis of a critically sized segmental defect of femoral diaphysis in the miniature pig. The results of this study will allow reducing implant failures in time-and cost-demanding transplantation experiments focused on bone healing. Compared to the six-hole 3.5 mm LCP, the five-hole titanium 4.5 mm LCP is more suitable implant for flexible bridging osteosynthesis of a critically sized segmental defect of femoral diaphysis in the miniature pig. The results of this study will allow reducing implant failures in time-and cost-demanding transplantation experiments focused on bone healing.

In Czech

Pětiděrová titanová 4,5 mm LCP se v porovnání s šestiděrovou 3,5 mm LCP jeví jako vhodnější implantát k provedení flexibilní pilířové osteosyntézy velkého segmentálního defektu diafýzy femuru u miniaturního prasete jako zvířecího experimentálního modelu. Výsledky této studie umožní omezit nežádoucí selhání implantátů při časově a finančně náročných transplantačních experimentech zaměřených na hojení kostí.

Links

2B06130, research and development project
Name: Využití nově syntetizovaných biomateriálů v kombinaci s kmenovými buňkami v léčbě chorob, které postihují lidské tkáně derivované z mesodermu: chrupavku, kost, vazy a menisky. (Acronym: Chondros)
Investor: Ministry of Education, Youth and Sports of the CR