HSIEH, Yi-Ting, Wen-Tsen CHEN, Iva TOMALOVÁ, Jan PREISLER a Huan-Tsung CHANG. Detection of melamine in infant formula and grain powder by surface-assisted laser desorption/ionization mass spectrometry. Rapid Communications in Mass Spectrometry. Wiley InterScience, 2012, roč. 26, č. 12, s. 1393-1398. ISSN 0951-4198. Dostupné z: https://dx.doi.org/10.1002/rcm.6238.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Detection of melamine in infant formula and grain powder by surface-assisted laser desorption/ionization mass spectrometry
Autoři HSIEH, Yi-Ting (158 Tchaj-wan), Wen-Tsen CHEN (158 Tchaj-wan), Iva TOMALOVÁ (203 Česká republika, domácí), Jan PREISLER (203 Česká republika, garant, domácí) a Huan-Tsung CHANG (158 Tchaj-wan).
Vydání Rapid Communications in Mass Spectrometry, Wiley InterScience, 2012, 0951-4198.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.509
Kód RIV RIV/00216224:14740/12:00057422
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1002/rcm.6238
UT WoS 000304154300001
Klíčová slova anglicky Melamine; Gold Nanoparticles; SALDI MS
Štítky ok, rivok
Příznaky Recenzováno
Změnil Změnil: prof. Mgr. Jan Preisler, Ph.D., učo 45329. Změněno: 15. 2. 2018 22:17.
Anotace
We have developed a method for the determination of melamine (MEL), ammeline (AMN), and ammelide (AMD) by surface-assisted laser desorption/ionization mass spectrometry (SALDI-MS) using gold nanoparticles (Au NPs). The major peaks for MEL, AMN, and AMD at m/z 127.07, 128.05, and 129.04 are assigned to the [MEL + H]+, [AMN + H]+, and [AMD + H]+ ions. Because the three tested compounds adsorb weakly onto the surfaces of the Au NPs through Au–N bonding, they can be easily concentrated from complex samples by applying a simple trapping/centrifugation process. The SALDI-MS method provides limits of detection of 5, 10, and 300 nM for MEL, AMN, and AMD, respectively, at a signal-to-noise ratio of 3. The signal variation for 150-shot average spectra of the three analytes within the same spot was 15%, and the batch-to-batch variation was 20%. We have validated the practicality of this approach by the analysis of these three analytes in infant formula and grain powder. This simple and rapid SALDI-MS approach holds great potential for screening of MEL in foods.
Návaznosti
ED1.1.00/02.0068, projekt VaVNázev: CEITEC - central european institute of technology
GCP206/10/J012, projekt VaVNázev: Analýza biomolekul hmotnostní spektrometrií s laserovou desorpcí/ionizací za účasti nanomateriálů
Investor: Grantová agentura ČR, Analýza biomolekul hmotnostní spektrometrií s laserovou desorpcí/ionizací za účasti nanomateriálů
VytisknoutZobrazeno: 25. 4. 2024 14:03