a 2012

Utilization of the anodic electro-osmotic flow for an amino acids profiling by capillary electrophoresis

MÁDR, Aleš, Kateřina SVOBODOVÁ, Jindra MUSILOVÁ and Zdeněk GLATZ

Basic information

Original name

Utilization of the anodic electro-osmotic flow for an amino acids profiling by capillary electrophoresis

Name in Czech

Využití anodického elektroosmotického toku pro aminokyselinové profilování pomocí kapilární elektroforézy

Authors

MÁDR, Aleš (203 Czech Republic, guarantor, belonging to the institution), Kateřina SVOBODOVÁ (203 Czech Republic, belonging to the institution), Jindra MUSILOVÁ (203 Czech Republic, belonging to the institution) and Zdeněk GLATZ (203 Czech Republic, belonging to the institution)

Edition

9th International Interdisciplinary Meeting on Bioanalysis, 2012

Other information

Language

English

Type of outcome

Konferenční abstrakt

Field of Study

10600 1.6 Biological sciences

Country of publisher

Czech Republic

Confidentiality degree

není předmětem státního či obchodního tajemství

RIV identification code

RIV/00216224:14310/12:00057816

Organization unit

Faculty of Science

ISBN

978-80-904959-1-3

UT WoS

000329635000068

Keywords (in Czech)

kapilární elektroforéza; anodický elektroosmotický tok; bezkontaktní vodivostní detekce

Keywords in English

capillary electrophoresis; anodic electro-osmotic flow; contactless conductivity detection

Tags

Změněno: 21/1/2014 15:06, prof. RNDr. Zdeněk Glatz, CSc.

Abstract

V originále

Amino acid profiling is sometimes considered to be a supplementary analysis for diagnostic purposes. Detection of amino acids by conventional spectrophotometric techniques is hindered by lack of chromophores in their structures, thus derivatization step in a sample treatment protocol has to occur. However, amino acids in their native form can be detected by other detection techniques, e.g. mass spectrometry or capacitively coupled contactless conductivity detection (C4D). C4D is a non specific detection technique suitable for detection of ionic species and was successfully used for determination of amino acids. Completely resolved peaks were obtained only when long capillaries and electro-osmotic flow (EOF) suppression were applied. However, effective separation time of analytes of interest can be altered by EOF modification. Induction of the anodic EOF for amino acid profiling in the shorter capillaries is the subject of presented contribution.

In Czech

Aminokyselinové profilování se někdy využívá jako doplňkové diagnostické vyšetření. Detekce aminokyselin v nativní formě spektrofotometrickými technikami je v důsledku nepřítomnosti chromoforů v jejich struktuře nemožná. Z toho důvodu se aminokyseliny před samotným stanovením derivatizují. Detekce aminokyselin v jejich nativní formě je však možná za použití jiných detekčních technik, např. hmotnostní spektrometrie nebo bezkontaktní vodivostní detekce (C4D). C4D je nespecifickou detekční technikou, která je vhodná pro detekci iontů a byla úspěšně využita pro stanovení aminokyselin. K úplnému rozlišení aminokyselin bylo zapotřebí dlouhé kapiláry a potlačení elektroosmotického toku (EOF). Efektivní separační čas analytů lze však upravit změnou EOF. Zavedení anodického EOF pro aminokyselinové profilování v krátkých kapilárách je předmětem tohoto příspěvku.

Links

GAP206/11/0009, research and development project
Name: Kapilární electroforéza jako nástroj pro metabolomické studie (Acronym: CE metabolomics)
Investor: Czech Science Foundation
GBP206/12/G014, research and development project
Name: Centrum pokročilých bioanalytických technologií