Detailed Information on Publication Record
2012
Utilization of the anodic electro-osmotic flow for an amino acids profiling by capillary electrophoresis
MÁDR, Aleš, Kateřina SVOBODOVÁ, Jindra MUSILOVÁ and Zdeněk GLATZBasic information
Original name
Utilization of the anodic electro-osmotic flow for an amino acids profiling by capillary electrophoresis
Name in Czech
Využití anodického elektroosmotického toku pro aminokyselinové profilování pomocí kapilární elektroforézy
Authors
MÁDR, Aleš (203 Czech Republic, guarantor, belonging to the institution), Kateřina SVOBODOVÁ (203 Czech Republic, belonging to the institution), Jindra MUSILOVÁ (203 Czech Republic, belonging to the institution) and Zdeněk GLATZ (203 Czech Republic, belonging to the institution)
Edition
9th International Interdisciplinary Meeting on Bioanalysis, 2012
Other information
Language
English
Type of outcome
Konferenční abstrakt
Field of Study
10600 1.6 Biological sciences
Country of publisher
Czech Republic
Confidentiality degree
není předmětem státního či obchodního tajemství
References:
RIV identification code
RIV/00216224:14310/12:00057816
Organization unit
Faculty of Science
ISBN
978-80-904959-1-3
UT WoS
000329635000068
Keywords (in Czech)
kapilární elektroforéza; anodický elektroosmotický tok; bezkontaktní vodivostní detekce
Keywords in English
capillary electrophoresis; anodic electro-osmotic flow; contactless conductivity detection
Tags
Změněno: 21/1/2014 15:06, prof. RNDr. Zdeněk Glatz, CSc.
V originále
Amino acid profiling is sometimes considered to be a supplementary analysis for diagnostic purposes. Detection of amino acids by conventional spectrophotometric techniques is hindered by lack of chromophores in their structures, thus derivatization step in a sample treatment protocol has to occur. However, amino acids in their native form can be detected by other detection techniques, e.g. mass spectrometry or capacitively coupled contactless conductivity detection (C4D). C4D is a non specific detection technique suitable for detection of ionic species and was successfully used for determination of amino acids. Completely resolved peaks were obtained only when long capillaries and electro-osmotic flow (EOF) suppression were applied. However, effective separation time of analytes of interest can be altered by EOF modification. Induction of the anodic EOF for amino acid profiling in the shorter capillaries is the subject of presented contribution.
In Czech
Aminokyselinové profilování se někdy využívá jako doplňkové diagnostické vyšetření. Detekce aminokyselin v nativní formě spektrofotometrickými technikami je v důsledku nepřítomnosti chromoforů v jejich struktuře nemožná. Z toho důvodu se aminokyseliny před samotným stanovením derivatizují. Detekce aminokyselin v jejich nativní formě je však možná za použití jiných detekčních technik, např. hmotnostní spektrometrie nebo bezkontaktní vodivostní detekce (C4D). C4D je nespecifickou detekční technikou, která je vhodná pro detekci iontů a byla úspěšně využita pro stanovení aminokyselin. K úplnému rozlišení aminokyselin bylo zapotřebí dlouhé kapiláry a potlačení elektroosmotického toku (EOF). Efektivní separační čas analytů lze však upravit změnou EOF. Zavedení anodického EOF pro aminokyselinové profilování v krátkých kapilárách je předmětem tohoto příspěvku.
Links
GAP206/11/0009, research and development project |
| ||
GBP206/12/G014, research and development project |
|