ŠLAISOVÁ, Radka, Karel BENDA, Jiří JARKOVSKÝ, Hana PETRÁŠOVÁ, Petr SZTURZ a Vlastimil VÁLEK. Contrast-enhanced ultrasonography compared to gray-scale and power doppler in the diagnosis of peripheral lymphadenopathy. European Journal of Radiology. CLARE: ELSEVIER IRELAND LTD, 2013, roč. 82, č. 4, s. 693-698. ISSN 0720-048X. Dostupné z: https://dx.doi.org/10.1016/j.ejrad.2012.12.008.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Contrast-enhanced ultrasonography compared to gray-scale and power doppler in the diagnosis of peripheral lymphadenopathy
Autoři ŠLAISOVÁ, Radka (203 Česká republika, garant, domácí), Karel BENDA (203 Česká republika, domácí), Jiří JARKOVSKÝ (203 Česká republika, domácí), Hana PETRÁŠOVÁ (703 Slovensko, domácí), Petr SZTURZ (203 Česká republika, domácí) a Vlastimil VÁLEK (203 Česká republika, domácí).
Vydání European Journal of Radiology, CLARE, ELSEVIER IRELAND LTD, 2013, 0720-048X.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30200 3.2 Clinical medicine
Stát vydavatele Irsko
Utajení není předmětem státního či obchodního tajemství
WWW Full Text
Impakt faktor Impact factor: 2.160
Kód RIV RIV/00216224:14110/13:00067632
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1016/j.ejrad.2012.12.008
UT WoS 000316740000027
Klíčová slova anglicky Lymph nodes; Ultrasonography; Color Doppler; Contrast media
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Marie Šípková, DiS., učo 437722. Změněno: 17. 12. 2019 10:15.
Anotace
Objectives: The aim of the study was to evaluate the ability of contrast-enhanced ultrasonography compared to gray-scale B-mode and power Doppler in distinction between benign and malignant lymphadenopathy. Methods: In a prospective study ultrasonography was performed in 133 patients with superficial lymphadenopathy (73 men, 60 women; mean age of 51 years, range: 18-86 years), who were examined for palpable mass in the neck, axilla or groin (104/133) and for clinical suspicion of lymphoma on the basis of positive PET/CT (29/133). 133 nodes were examined, subsequently preoperatively localized under ultrasound guidance and surgically removed; longitudinal to transverse ratio, location of nodal vessels by power Doppler and pattern of enhancement by contrast-enhanced ultrasonography with 1.5 ml intravenous bolus of sulphur hexafluoride contrast agent were documented. The ultrasound findings were compared with the histology. Results: Of all the nodes extirpated, 33 were benign, 100 were malignant (40 metastases, 60 lymphomas). Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of conventional techniques were 72%, 63.6%, 85.7%, 42.9%, 67.8% for longitudinal to transverse ratio; 73%, 60.6%, 84.9%, 42.6%, 68.3% for power Doppler versus 98.0%, 54.5%, 86.7%, 90.0%, 76.3% for contrast-enhanced ultrasonography according to Receiver Operating Characteristic analysis. Conclusions: Receiver Operating Characteristic analysis confirmed higher degree of diagnostic accuracy of contrast-enhanced ultrasonography in comparison with conventional techniques. Evaluation of nodal perfusion after intravenous administration of microbubble contrast agent can be helpful in differentiation of benign from malignant nodes.
VytisknoutZobrazeno: 12. 5. 2024 21:24