SPILKA, J., V. CHUDÁČEK, M. BURŠA, L. ZACH, M. HUPTYCH, L. LHOTSKÁ, Petr JANKŮ a Lukáš HRUBAN. Stability of variability Features Computed from Fetal heart Rate with Artificially Infused Missing Data. In Alan Murray. Computing in Cardiology. New York: Computing in Cardiology, 2012, s. 917-920. ISBN 978-1-4673-2074-0.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Stability of variability Features Computed from Fetal heart Rate with Artificially Infused Missing Data
Autoři SPILKA, J. (203 Česká republika, garant), V. CHUDÁČEK (203 Česká republika), M. BURŠA (203 Česká republika), L. ZACH (203 Česká republika), M. HUPTYCH (203 Česká republika), L. LHOTSKÁ (203 Česká republika), Petr JANKŮ (203 Česká republika, domácí) a Lukáš HRUBAN (203 Česká republika, domácí).
Vydání New York, Computing in Cardiology, od s. 917-920, 4 s. 2012.
Nakladatel Computing in Cardiology
Další údaje
Originální jazyk angličtina
Typ výsledku Stať ve sborníku
Obor 30201 Cardiac and Cardiovascular systems
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
Forma vydání tištěná verze "print"
WWW URL
Kód RIV RIV/00216224:14110/12:00063998
Organizační jednotka Lékařská fakulta
ISBN 978-1-4673-2074-0
ISSN 2325-8861
UT WoS 000320270700230
Klíčová slova anglicky Fetal heart rate; undistorted signal; distorted signal; De Haan index; Yeh index
Změnil Změnila: Ing. Mgr. Věra Pospíšilíková, učo 9005. Změněno: 25. 2. 2013 05:10.
Anotace
Fetal heart rate (FHR) is usually the only measurement acquired directly from the fetus during delivery; therefore, any distortion leading to a corrupted signal means difficulties for fetal surveillance. Obstetricians use morphological features for evaluation of FHR that are usually estimated visually. Other type of features are those that are either difficult to estimate visually or can not be estimated by naked eye at all. In this paper we examined several STV (short), LTV (long term variability) features and one nonlinear feature. We compared features for an undistorted and distorted signal with missing samples. We analyzed feature’s stability with respect to acquisition technique (ultrasound measurement, direct ECG measurement). The stability of STV indicies were almost identical except standard STV, De Haan index, and Yeh index. These indices changed markedly with increasing percentage of missing samples; Yeh index decreased up to 70% of its nominal value and De Haan index increased up to 350%; this behavior held for FHR recorded using ultrasound measurement and even for FHR directly computed from fetal ECG. This relationship was present for beat-to-beat variability and disappeared for epoch-to-epoch variability.