ODRÁŠKA, Pavel, Lenka DOLEZALOVA, Jan KUTA, Michal ORAVEC, Pavel PILER a Luděk BLÁHA. Evaluation of the Efficacy of Additional Measures Introduced for the Protection of Healthcare Personnel Handling Antineoplastic Drugs. ANNALS OF OCCUPATIONAL HYGIENE. OXFORD: OXFORD UNIV PRESS, 2013, roč. 57, č. 2, s. 240-250. ISSN 0003-4878. Dostupné z: https://dx.doi.org/10.1093/annhyg/mes057.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Evaluation of the Efficacy of Additional Measures Introduced for the Protection of Healthcare Personnel Handling Antineoplastic Drugs
Autoři ODRÁŠKA, Pavel (203 Česká republika, garant), Lenka DOLEZALOVA (203 Česká republika), Jan KUTA (203 Česká republika, domácí), Michal ORAVEC (203 Česká republika, domácí), Pavel PILER (203 Česká republika, domácí) a Luděk BLÁHA (203 Česká republika, domácí).
Vydání ANNALS OF OCCUPATIONAL HYGIENE, OXFORD, OXFORD UNIV PRESS, 2013, 0003-4878.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30104 Pharmacology and pharmacy
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 2.068
Kód RIV RIV/00216224:14310/13:00067961
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1093/annhyg/mes057
UT WoS 000315158600008
Klíčová slova anglicky chemical analysis; cytotoxic drugs; hazardous pharmaceuticals; occupational exposure; safety engineering
Štítky AKR, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnil: prof. RNDr. Luděk Bláha, Ph.D., učo 15473. Změněno: 4. 4. 2014 20:35.
Anotace
Antineoplastic drugs are considered as a potential health risk to healthcare personnel, due to their adverse effects. The objective of the study was to compare the surface contamination level of the conventional preparation room and outpatient clinic before and after the implementation of a set of additional protective measures. To determine the surface contamination level with antineoplastic drugs, cyclophosphamide and platinum were determined in wipe samples with high performance liquid chromatography with tandem mass spectrometry and inductively coupled plasma mass spectrometry.In the preparation room, depending on the sampling spot and analyte, median concentrations ranged from 5 to 267 pg cm(2) and from 2 to 368 pg cm(2) before and after implementation of the measures, respectively. In the outpatient clinic, median concentrations ranged from 5 to 5310 pg cm(2) and from < 0.2 to 574 pg cm(2) before and after implementation of the measures, respectively. Depending on the sampling spot, median contamination of the outpatient clinic with cyclophosphamide and platinum was reduced by 5799% and 6198%, respectively.The measures implemented in the outpatient clinic were shown to reduce workplace contamination effectively. Therefore, they can be recommended also for other workplaces where antineoplastic drugs are administered. In contrast, measures implemented in the preparation room, where relatively strict regulations had already been adopted before the study, were less effective. To decrease the actual contamination of the preparation room, other protective measures (e.g. closed-system transfer devices) should be considered.
Návaznosti
ED0001/01/01, projekt VaVNázev: CETOCOEN
EE2.3.20.0053, projekt VaVNázev: Podpora odborníků a mezinárodního networkingu v oblastech environmentálního výzkumu v ČR
LM2011028, projekt VaVNázev: RECETOX ? Národní infrastruktura pro výzkum toxických látek v prostředí
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, RECETOX Národní infrastruktura pro výzkum toxických látek v prostředí
VytisknoutZobrazeno: 7. 8. 2024 14:13