J 2013

Intracerebrally recorded high frequency oscillations: Simple visual assessment versus automated detection

PAIL, Martin, Josef HALÁMEK, Pavel DANIEL, Robert KUBA, Ivana TYRLÍKOVÁ et. al.

Základní údaje

Originální název

Intracerebrally recorded high frequency oscillations: Simple visual assessment versus automated detection

Autoři

PAIL, Martin (203 Česká republika, domácí), Josef HALÁMEK (203 Česká republika), Pavel DANIEL (203 Česká republika, domácí), Robert KUBA (203 Česká republika, domácí), Ivana TYRLÍKOVÁ (203 Česká republika, domácí), Jan CHRASTINA (203 Česká republika, domácí), Pavel JURÁK (203 Česká republika), Ivan REKTOR (203 Česká republika, domácí) a Milan BRÁZDIL (203 Česká republika, garant, domácí)

Vydání

Clinical Neurophysiology, Clare, Elsevier Ireland, 2013, 1388-2457

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

30000 3. Medical and Health Sciences

Stát vydavatele

Irsko

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 2.979

Kód RIV

RIV/00216224:14740/13:00066144

Organizační jednotka

Středoevropský technologický institut

UT WoS

000324531400006

Klíčová slova anglicky

High frequency oscillations; Spikes; Ripples; Fast ripples; Temporal lobe epilepsy; Extratemporal lobe epilepsy; Seizure onset zone; Epileptogenic zone

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 17. 10. 2013 13:16, Olga Křížová

Anotace

V originále

Objective: We compared the possible contribution (in the detection of seizure onset zone – SOZ) of simple visual assessment of intracerebrally recorded high-frequency oscillations (HFO) with standard automated detection. Methods: We analyzed stereo-EEG (SEEG) recordings from 20 patients with medically intractable partial seizures (10 temporal/10 extratemporal). Independently using simple visual assessment and automated detection of HFO, we identified the depth electrode contacts with maximum occurrences of ripples (R) and fast ripples (FR). The SOZ was determined by independent visual identification in standard SEEG recordings, and the congruence of results from visual versus automated HFO detection was compared. Results: Automated detection of HFO correctly identified the SOZ in 14 (R)/10 (FR) out of 20 subjects; a simple visual assessment of SEEG recordings in the appropriate frequency ranges correctly identified the SOZ in 13 (R)/9 (FR) subjects. Conclusions: Simple visual assessment of SEEG traces and standard automated detection of HFO seem to contribute comparably to the identification of the SOZ in patients with focal epilepsies. When using macroelectrodes in neocortical extratemporal epilepsies, the SOZ might be better determined by the ripple range. Significance: Standard automated detection of HFO enables the evaluation of HFO characteristics in whole data. This detection allows general purpose and objective evaluation, without any bias from the neurophysiologist’s experiences and practice

Návaznosti

ED1.1.00/02.0068, projekt VaV
Název: CEITEC - central european institute of technology
GAP103/11/0933, projekt VaV
Název: Analýza vysokofrekvenčního EEG signálu z hlubokých mozkových elektrod
Investor: Grantová agentura ČR, Analýza vysokofrekvenčního EEG signálu z hlubokých mozkových elektrod
MSM0021622404, záměr
Název: Vnitřní organizace a neurobiologické mechanismy funkčních systémů CNS
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Vnitřní organizace a neurobiologické mechanismy funkčních systémů CNS