Potential use of V-channel Ge(220) monochromators in X-ray metrology and imaging
KORYTÁR, D., P. VAGOVIČ, K. VÉGSÖ, P. ŠIFFALOVIČ, E. DOBROČKA et. al.Základní údaje
Originální název
Potential use of V-channel Ge(220) monochromators in X-ray metrology and imaging
Autoři
KORYTÁR, D. (703 Slovensko), P. VAGOVIČ (703 Slovensko), K. VÉGSÖ (703 Slovensko), P. ŠIFFALOVIČ (703 Slovensko), E. DOBROČKA (703 Slovensko), W. JARK (380 Itálie), V. ÁČ (703 Slovensko), Z. ZÁPRAŽNÝ (703 Slovensko), C. FERRARI (380 Itálie), A. CECILIA (703 Slovensko), E. HAMANN (276 Německo), Petr MIKULÍK (203 Česká republika, garant, domácí), T. BAUMBACH (276 Německo), M. FIEDERLE (276 Německo) a M. JERGEL (703 Slovensko)
Vydání
Journal of Applied Crystallography, Hoboken, WILEY-BLACKWELL, 2013, 0021-8898
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10302 Condensed matter physics
Stát vydavatele
Spojené státy
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 3.950
Kód RIV
RIV/00216224:14740/13:00069091
Organizační jednotka
Středoevropský technologický institut
UT WoS
000322032300019
Klíčová slova anglicky
x-ray optics; monochromators; imaging
Štítky
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 6. 4. 2014 23:17, Olga Křížová
Anotace
V originále
While channel-cut crystals, in which the diffracting surfaces in an asymmetric cut are kept parallel, can provide beam collimation and spectral beam shaping, they can in addition provide beam compression or expansion if the cut is V-shaped. The compression/expansion ratio depends in this case on the total asymmetry factor. If the Ge(220) diffraction planes and a total asymmetry factor in excess of 10 are used, the rocking curves of two diffractors will have a sufficient overlap only if the second diffractor is tuned slightly with respect to the first one. This study compares and analyses several ways of overcoming this mismatch, which is due to refraction, when the Cu K1 beam is compressed 21-fold in a V21 monochromator. A more than sixfold intensity increase was obtained if the matching was improved either by a compositional variation or by a thermal deformation. This provided an intensity gain compared with the use of a simple slit in a symmetrical channel-cut monochromator. The first attempt to overcome the mismatch by introducing different types of X-ray prisms for the required beam deflection is described as well. The performance of the V-shaped monochromators is demonstrated in two applications. A narrow collimated monochromatic beam obtained in the beam compressing mode was used for high-resolution grazing-incidence small-angle X-ray scattering measurements of a silicon sample with corrupted surface. In addition, a two-dimensional Bragg magnifier, based on two crossed V15 channel monochromators in beam expansion mode and tuned by means of unequal asymmetries, was successfully applied to high-resolution imaging of test structures in combination with a Medipix detector.