REPRODUCIBILITY OF MEASURING THE CARDIO-ANKLE VASCULAR INDEX (CAVI) TO ASSESS ARTERIAL STIFFNESS USING VASCULAR SCREENING SYSTEM
PLUHÁČEK, Zdeněk, Radka ŠTĚPÁNOVÁ, Jindřich FIALA, Petr DOBŠÁK, Francesco LOPEZ-JIMENEZ et. al.Základní údaje
Originální název
REPRODUCIBILITY OF MEASURING THE CARDIO-ANKLE VASCULAR INDEX (CAVI) TO ASSESS ARTERIAL STIFFNESS USING VASCULAR SCREENING SYSTEM
Název česky
Reproducibilita měření CAVI
Autoři
PLUHÁČEK, Zdeněk, Radka ŠTĚPÁNOVÁ, Jindřich FIALA, Petr DOBŠÁK, Francesco LOPEZ-JIMENEZ a Ondřej SOCHOR
Vydání
XXII. výroční sjezd České kardiologické společnosti, 2014
Další údaje
Jazyk
angličtina
Typ výsledku
Prezentace na konferencích
Obor
30201 Cardiac and Cardiovascular systems
Stát vydavatele
Česká republika
Utajení
není předmětem státního či obchodního tajemství
Organizační jednotka
Lékařská fakulta
Změněno: 18. 5. 2014 13:19, MUDr. Zdeněk Pluháček
Anotace
V originále
Introduction and aim: Arterial stiffness generally reflects atherosclerosis and can be measured using different methods. In Kardiovize 2030, a cross-sectional study monitoring prevalence of cardiovascular risk factors in the city of Brno, we use vascular screening system Vasera 1500® (Fukuda Denshi, Japan) to determine CAVI. It contains 4 blood pressure cuffs with sensors (to measure blood pressure and generate plethysmograms), ECG leads and a phonocardiograph (microphone recording heart sounds). Using these monitors, CAVI is calculated. Good reproducibility of such measurement is essential to evaluate arterial stiffness but current evidence is limited to studies with only a few participants. Methods: During 6 months we investigated 212 people aged 26-45 years (36.4±5.5 yr) with no history of cardiovascular events. Every volunteer had a CAVI measured twice within 5 minutes according to the standard guidelines by a trained nurse. We calculated the average CAVI for each attempt. Then we analyzed these two averages in order to examine the reliability and reproducibility of the measurements using the Bland-Altman plot and test. Results: There was only a slight mean difference between CAVI measurements (-0.018 ± 0.60). The intra-class correlation coefficient and standard error of the mean were R=0.72, SEM=0.32, respectively, proving a good reproducibility of the device to measure CAVI. Conclusion: CAVI measurement using vascular screening system Vasera 1500® is a method to asses arterial stiffness with very good reproducibility in young healthy volunteers. Supported by European Regional Development Fund - Project FNUSA-ICRC (No. CZ.1.05/1.1.00/02.0123) and Ministry of Health - grant IGA (NT13434-4/2012)