VRBKOVÁ, Blanka, Vendula ROBLOVÁ, Edward S. YEUNG a Jan PREISLER. Determination of sterols using liquid chromatography with off-line surface-assisted laser desorption/ionization mass spectrometry. Journal of Chromatography A. Amsterdam: Elsevier, 2014, roč. 1358, 5 September, s. 102-109. ISSN 0021-9673. Dostupné z: https://dx.doi.org/10.1016/j.chroma.2014.06.077.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Determination of sterols using liquid chromatography with off-line surface-assisted laser desorption/ionization mass spectrometry
Autoři VRBKOVÁ, Blanka (203 Česká republika, domácí), Vendula ROBLOVÁ (203 Česká republika, domácí), Edward S. YEUNG (840 Spojené státy) a Jan PREISLER (203 Česká republika, garant, domácí).
Vydání Journal of Chromatography A, Amsterdam, Elsevier, 2014, 0021-9673.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Nizozemské království
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 4.169
Kód RIV RIV/00216224:14740/14:00073825
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1016/j.chroma.2014.06.077
UT WoS 000340979200013
Klíčová slova anglicky sterols; SALDI MS; HPLC
Štítky kontrola MP, podil, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnil: prof. Mgr. Jan Preisler, Ph.D., učo 45329. Změněno: 15. 2. 2018 22:08.
Anotace
A new method, reversed phase liquid chromatography with off-line surface-assisted laser desorption/ionization mass spectrometry (RPLC–SALDI MS) for the determination of brassicasterol (BR), cholesterol (CH), stigmasterol (ST), campesterol (CA) and b-sitosterol (SI) in oil samples has been developed. The sample preparation consisted of alkaline saponification followed by extraction of the unsaponificable fraction with diethyl ether. The recovery of the sterols ranged from 91 to 95% with RSD less than 4%. Separation of the five major sterols on a C18 column using methanol-water gradient was achieved in about 10 min. An on-line UV detector was employed for the initial sterol detection prior to effluent deposition using a laboratory-built spotter with 1:73 splitter. Off-line SALDI MS was then applied for mass determination/identification and quantification of the separated sterols. Ionization of the nonpolar analytes was achieved by silver ion cationization with silver nanoparticles used as the SALDI matrix providing limits of detection 12, 6 and 11 fmol for CH, ST and SI, respectively. Because of the incorporated splitter, the effective limits of detection of the RPLC–SALDI MS analysis were 4, 3 and 4 pmol (or 0.08, 0.06 and 0.08 ug/mL) for CH, ST and SI, respectively. For quantification, 6-ketocholestanol (KE) was used as the internal standard. The method has been applied for the identification and quantification of sterols in olive, linseed and sunflower oil samples. The described off-line coupling of RPLC to SALDI MS represents an alternative to GC–MS for analysis of nonpolar compounds.