2014
Simultaneous measurements of PSII activity and thallus temperature during linear cooling. A method to assess interspecific differences in photosynthetic processes in lichens from polar regions.
HÁJEK, Josef; Peter VÁCZI; Jana HAZDROVÁ a Miloš BARTÁKZákladní údaje
Originální název
Simultaneous measurements of PSII activity and thallus temperature during linear cooling. A method to assess interspecific differences in photosynthetic processes in lichens from polar regions.
Název česky
Souběžná měření aktivity PSII a teploty stélky během lineárního ochlazování. Metoda pro posouzení mezidruhových rozdílů ve fotosyntetických procesech lišejníků z polárních oblastí
Autoři
HÁJEK, Josef (203 Česká republika, garant, domácí); Peter VÁCZI (703 Slovensko); Jana HAZDROVÁ (203 Česká republika, domácí) a Miloš BARTÁK (203 Česká republika, domácí)
Vydání
Polar Ecology Conference, Ceske Budejovice, p. 56-57. 2014
Další údaje
Jazyk
angličtina
Typ výsledku
Konferenční abstrakt
Obor
10600 1.6 Biological sciences
Stát vydavatele
Česká republika
Utajení
není předmětem státního či obchodního tajemství
Kód RIV
RIV/00216224:14310/14:00076590
Organizační jednotka
Přírodovědecká fakulta
ISBN
978-80-7394-463-6
Klíčová slova česky
odolnost proti zmražení; fluorescence chlorofylu; lišejníkový fotobiont; stélka; kritická teplota
Klíčová slova anglicky
cryoresistance; chlorophyll fluorescence; thallus; lichen photobiont; critical temperature
Změněno: 25. 9. 2014 11:25, prof. Ing. Miloš Barták, CSc.
V originále
A comparison of cryoresistance of isolated lichen photobiont and polar lichens is presented. Several species were chosen for this experiment: (1) algal cultures of Trebouxia glomerata, Trebouxia sp. (2) thalli of Usnea antarctica, Usnea aurantiaco-atra, Usnea longissima, Umbilicaria decussata, Umbilicaria cylindrica. All the samples were exposed to temperatures linearly decreasing from +20 °C to -40 °C under controlled conditions. During the experiment, sample temperature and two parameters of chlorophyll fluorescence – (1) potential (FV/FM) and (2) effective quantum yield of photochemical processes in photosystem II (YieldPSII) – were measured simultaneously. Cooling was provided by a KRYO 560-16 (PLANER, United Kingdom) device. For majority of samples, two cooling rates were used: 6 °C min-1 (fast) and 2 °C min-1 (slow) were used. The chlorophyll fluorescence was measured by a PC-linked PAM 2000 fluorometer (H. Walz, Germany). Measurements of YieldPSII were made every 30 s. For all samples, the response of FV/FM and YieldPSII to declining temperature showed an „S curve“ with critical temperatures, indicating high level of cryoresistance of the samples. In an individual sample, critical temperature for FV/FM was typically lower than for YieldPSII.
Česky
viz abstrakt v anglictine
Návaznosti
LM2010009, projekt VaV |
|