2015
Self-expandable biodegradable biliary stents in porcine model
GROLICH, Tomáš, Michal CRHA, Ladislav NOVOTNÝ, Zdeněk KALA, Aleš HEP et. al.Základní údaje
Originální název
Self-expandable biodegradable biliary stents in porcine model
Autoři
GROLICH, Tomáš (203 Česká republika, garant, domácí), Michal CRHA (203 Česká republika), Ladislav NOVOTNÝ (203 Česká republika), Zdeněk KALA (203 Česká republika, domácí), Aleš HEP (203 Česká republika, domácí), Alois NEČAS (203 Česká republika), Jan HLAVSA (203 Česká republika, domácí), Ladislav MITÁŠ (203 Česká republika, domácí) a Jan MISÍK (203 Česká republika)
Vydání
Journal of Surgical Research, San Diego, Academic Press, 2015, 0022-4804
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
30200 3.2 Clinical medicine
Stát vydavatele
Spojené státy
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 2.198
Kód RIV
RIV/00216224:14110/15:00082127
Organizační jednotka
Lékařská fakulta
UT WoS
000346244300014
Klíčová slova anglicky
Biliary tree; Biodegradable stent; Polydioxanon
Štítky
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 27. 2. 2015 15:09, Ing. Mgr. Věra Pospíšilíková
Anotace
V originále
Background: Treatment or prevention of a benign biliary tree stricture is an unresolved problem. A novel self-expandable biodegradable polydioxanon biliary stent in a porcine model was studied. Materials and methods: This new stent was used in 23 pigs. Feasibility and safety of surgical stenting, time of biodegradation, and histologic reaction in 2, 8, 13, and 20 wk of a follow-up were studied. All stents were inserted into a common bile duct through a duodenal papilla following small dilatation. After surgical evaluation of abdominal cavities, the pigs were sacrificed to remove common bile ducts with the stents. All bile ducts were assessed by macroscopic and histopathologic examination. Results: Self-expansion was correct in all cases. Neither bile duct obstruction nor postsurgical complications were observed. Macroscopic evaluation indicated lightening of the stent color in 2 wk, a partial disintegration in 8 wk, and a complete absorption in 13 and 20 wk. Histologic evaluation in general substantiated a mild-to-moderate inflammatory reaction in the lamina propria during the whole follow up and had no clinical consequences. No cholangitis, necrosis, abscess, or excessive fibroplasia was found in a hepatoduodenal ligament. Conclusions: Our results suggest that polydioxanon biodegradable self-expanding stents seem to be useful for biliary system implantation, offer a good biocompatibility, and completely degrade within 13 wk.
Návaznosti
ED1.1.00/02.0068, projekt VaV |
| |
EE2.3.09.0193, projekt VaV |
|