HRDLIČKA, Aleš, Magda DVOŘÁKOVÁ, Pavel SLAVÍČEK, Lukáš NOVOSÁD, Vítězslav OTRUBA a Viktor KANICKÝ. Easily ionizable elements in analytical plasma pencil spectroscopy. In European Symposium on Atomic Spectrometry (ESAS) 2014 - 15th Czech - Slovak Spectroscopic Conference (15th CSSC). 2014. ISBN 978-80-905704-1-2.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Easily ionizable elements in analytical plasma pencil spectroscopy
Název česky Snadno ionizovatelné prvky v analytické spektroskopii s plazmovou tužkou
Autoři HRDLIČKA, Aleš (203 Česká republika, garant, domácí), Magda DVOŘÁKOVÁ (203 Česká republika, domácí), Pavel SLAVÍČEK (203 Česká republika, domácí), Lukáš NOVOSÁD (203 Česká republika, domácí), Vítězslav OTRUBA (203 Česká republika, domácí) a Viktor KANICKÝ (203 Česká republika, domácí).
Vydání European Symposium on Atomic Spectrometry (ESAS) 2014 - 15th Czech - Slovak Spectroscopic Conference (15th CSSC), 2014.
Další údaje
Originální jazyk angličtina
Typ výsledku Prezentace na konferencích
Obor 10402 Inorganic and nuclear chemistry
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
WWW stránkyESAS 2014 s programem
Kód RIV RIV/00216224:14740/14:00077812
Organizační jednotka Středoevropský technologický institut
ISBN 978-80-905704-1-2
Klíčová slova česky spektroskopie; plazmová tužka; snadno ionizovatelné prvky; analýza
Klíčová slova anglicky spectroscopy; plasma pencil; easily ionizable elements; analysis
Příznaky Mezinárodní význam
Změnil Změnil: Mgr. Aleš Hrdlička, Ph.D., učo 22863. Změněno: 17. 12. 2014 16:31.
Anotace
Any discharge based excitation source may suffer from some matrix interferences. Especially easily ionizable elements from the group of alkali metals and also alkali earths can be a major source of these effects. Herein we present an experimental study describing the influence of these elements on measured spectral lines intensities and analytical results for some selected analytes. Similarly to previous studies with inductively coupled plasma a depression of the measured signals occurred in most cases. A strong decrease was observed in dependence on the concentration of the interferent while the influence of the analyte concentration is almost negligible. The dependence of the analyte signal decrease on the interferent concentration is not linear. Addition of e.g. sodium chloride causes a steep decrease of copper signal for a relatively narrow range 0-0.2 g l-1 of NaCl. Higher NaCl concentrations bring only moderate signal suppression. In comparison with other lines of elements showing different matrix effects the Na-Cu atomic interaction can be modeled by inelastic collisions of Na-Cu excited atoms with very similar energetic levels. The influence of the interferents on the plasma properties was monitored by calculation of excitation and rotational temperatures and electron number density.
Anotace česky
Při použití excitačních zdrojů na bázi výbojů se téměř vždy objevují matriční jevy, kdy některé složky matrice potlačují, a tím i zkreslují měřený signál analytu. Takovými inerferenty jsou i snadno ionizovatelné prvky, jako alkalické kovy a kovy alkalických zemin. Proto se studoval vliv při excitaci plazmovou tužkou. Největší pokles signálu analytu, např. Cu, byl zaznamenán v intervalu koncentrací 0-0,2 g/l NaCl jako interferentu. Mechanizmus interakce analytu s interferentem může být modelován nepružnými srážkami atomů, např. Cu-Na, při kterých hraje roli blízkost energetických hladin. Tyto jevy se též sledovaly v závislosti na excitační a rotační teplotě a hustotě elektronů ve výboji.
Návaznosti
ED1.1.00/02.0068, projekt VaVNázev: CEITEC - central european institute of technology
ED2.1.00/03.0086, projekt VaVNázev: Regionální VaV centrum pro nízkonákladové plazmové a nanotechnologické povrchové úpravy
VytisknoutZobrazeno: 14. 10. 2024 09:41