FARKA, Zdeněk, David KOVÁŘ a Petr SKLÁDAL. Rapid Detection of Microorganisms Based on Active and Passive Modes of QCM. Sensors. Basel, (Switzerland): MDPI AG, 2015, roč. 15, č. 1, s. 79-92. ISSN 1424-8220. Dostupné z: https://dx.doi.org/10.3390/s150100079.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Rapid Detection of Microorganisms Based on Active and Passive Modes of QCM
Autoři FARKA, Zdeněk (203 Česká republika, domácí), David KOVÁŘ (203 Česká republika, domácí) a Petr SKLÁDAL (203 Česká republika, garant, domácí).
Vydání Sensors, Basel, (Switzerland), MDPI AG, 2015, 1424-8220.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10600 1.6 Biological sciences
Stát vydavatele Švýcarsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.033
Kód RIV RIV/00216224:14740/15:00082200
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.3390/s150100079
UT WoS 000348309400005
Klíčová slova anglicky Escherichia coli; immunosensor; impedance analysis; label-free detection; quartz crystal microbalance
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnil: doc. Mgr. Zdeněk Farka, Ph.D., učo 357740. Změněno: 28. 9. 2017 11:06.
Anotace
Label-free immunosensors are well suited for detection of microorganisms because of their fast response and reasonable sensitivity comparable to infection doses of common pathogens. Active (lever oscillator and frequency counter) and passive (impedance analyzer) modes of quartz crystal microbalance (QCM) were used and compared for rapid detection of three strains of E. coli. Different approaches for antibody immobilization were compared, the immobilization of reduced antibody using Sulfo-SMCC was most effective achieving the limit of detection (LOD) 8 × 10^4 CFU·mL-1 in 10 min. For the passive mode, software evaluating impedance characteristics in real-time was developed and used. Almost the same results were achieved using both active and passive modes confirming that the sensor properties are not limited by the frequency evaluation method but mainly by affinity of the antibody. Furthermore, reference measurements were done using surface plasmon resonance. Effect of condition of cells on signal was observed showing that cells ruptured by ultrasonication provided slightly higher signal changes than intact microbes.