Další formáty:
BibTeX
LaTeX
RIS
@inproceedings{1214965, author = {Peterlík, Igor and Courtecuisse, Hadrien and Duriez, Christian and Cotin, Stephane}, address = {Neuveden}, booktitle = {Information Processing in Computer-Assisted Interventions}, doi = {http://dx.doi.org/10.1007/978-3-319-07521-1_21}, editor = {Stoyanov, Danail and Collins, D.Louis and Sakuma, Ichiro and Abolmaesumi, Purang and Jannin, Pierre}, keywords = {elastic registration; constrained dynamics; finite element method}, howpublished = {tištěná verze "print"}, language = {eng}, location = {Neuveden}, isbn = {978-3-319-07520-4}, pages = {196-205}, publisher = {Springer International Publishing}, title = {Model-Based Identification of Anatomical Boundary Conditions in Living Tissues}, year = {2014} }
TY - JOUR ID - 1214965 AU - Peterlík, Igor - Courtecuisse, Hadrien - Duriez, Christian - Cotin, Stephane PY - 2014 TI - Model-Based Identification of Anatomical Boundary Conditions in Living Tissues PB - Springer International Publishing CY - Neuveden SN - 9783319075204 KW - elastic registration KW - constrained dynamics KW - finite element method N2 - In this paper, we present a novel method dealing with the identification of boundary conditions of a deformable organ, a partic- ularly important step for the creation of patient-specific biomechani- cal models of the anatomy. As an input, the method requires a set of scans acquired in different body positions. Using constraint-based finite element simulation, the method registers the two data sets by solving an optimization problem minimizing the energy of the deformable body while satisfying the constraints located on the surface of the registered organ. Once the equilibrium of the simulation is attained (i.e. the organ registration is computed), the surface forces needed to satisfy the con- straints provide a reliable estimation of location, direction and magnitude of boundary conditions applied to the object in the deformed position. The method is evaluated on two abdominal CT scans of a pig acquired in flank and supine positions. We demonstrate that while computing a physically admissible registration of the liver, the resulting constraint forces applied to the surface of the liver strongly correlate with the loca- tion of the anatomical boundary conditions (such as contacts with bones and other organs) that are visually identified in the CT images. ER -
PETERLÍK, Igor, Hadrien COURTECUISSE, Christian DURIEZ a Stephane COTIN. Model-Based Identification of Anatomical Boundary Conditions in Living Tissues. In Stoyanov, Danail and Collins, D.Louis and Sakuma, Ichiro and Abolmaesumi, Purang and Jannin, Pierre. \textit{Information Processing in Computer-Assisted Interventions}. Neuveden: Springer International Publishing, 2014, s.~196-205. ISBN~978-3-319-07520-4. Dostupné z: https://dx.doi.org/10.1007/978-3-319-07521-1\_{}21.
|