2014
Comparison of different modifications of screen-printed working electrodes of electrochemical sensors using carbon nanotubes and plasma treatment
MAJZLÍKOVÁ, Petra, Jan PRÁŠEK, Marek ELIÁŠ, Ondřej JAŠEK, Jan PEKÁREK et. al.Základní údaje
Originální název
Comparison of different modifications of screen-printed working electrodes of electrochemical sensors using carbon nanotubes and plasma treatment
Název česky
Modifikace pracovních elektrod sítotiskem připravených elektrochemických senzorů v plazmatu
Autoři
MAJZLÍKOVÁ, Petra (203 Česká republika), Jan PRÁŠEK (203 Česká republika), Marek ELIÁŠ (203 Česká republika, garant, domácí), Ondřej JAŠEK (203 Česká republika, domácí), Jan PEKÁREK (203 Česká republika), Jaromír HUBÁLEK (203 Česká republika) a Lenka ZAJÍČKOVÁ (203 Česká republika, domácí)
Vydání
PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, WEINHEIM, WILEY-V C H VERLAG GMBH, 2014, 1862-6300
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10305 Fluids and plasma physics
Stát vydavatele
Německo
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 1.616
Kód RIV
RIV/00216224:14740/14:00074379
Organizační jednotka
Středoevropský technologický institut
UT WoS
000347182700014
Klíčová slova česky
uhlíkové nanotrubky; elektrochemické vlastnostnosti; plazmové opracování; senzory
Klíčová slova anglicky
carbon nanotubes; electrochemical properties; plasma treatment; sensors
Štítky
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 18. 3. 2015 08:12, Martina Prášilová
V originále
The screen-printed working electrode (WE) of an electrochemical sensor was modified with multi-walled carbon nanotubes (MWCNTs) and a plasma treatment. The plasma treatment was performed using radio frequency capacitively coupled discharge in Ar/O-2, Ar/cyclopropylamine and Ar/NH3. The surface of the WEs was characterized by scanning electron microscopy and their electrochemical behaviours were studied using potassium ferro/ferricyanide and dopamine as standard electrochemical probes. The most promising results were obtained with the electrodes modified by oxygen plasma because the reversibility and the current response were both improved significantly. The peak-to-peak separation improved from 879 to 116mV after the oxygen plasma treatment of the bare DuPont 7102 electrode. Spray-coated MWCNTs had a positive effect on the performance of the screen-printed DuPont 7102 WE if the sprayed MWCNTs layer was thicker. However, this improvement did not reach the performance of the screen-printed DuPont electrode modified by plasma oxidation. The modification by Ar/NH3 had weak influence on the response depending on the type of the electrode and plasma treatment in Ar/cyclopropylamine plasma led to an inhibition of the electrochemical reactivity due to a preparation of too thick insulating film.
Česky
Pracovní elektrody sítotiskem připravených elektrochemických senzorů byly modifikováný uhlíkovými nanotrubkami a ošetřeny v plazmatu.
Návaznosti
CZ.1.05/1.1.00/02.0068, interní kód MU |
| ||
GAP205/10/1374, projekt VaV |
|