Other formats:
BibTeX
LaTeX
RIS
@article{1231818, author = {Botto, Giovanni L. and Ricci, Renato P. and Benezet, Juan M. and Nielsen, Jens Cosedis and De Roy, Luc and Piot, Olivier and Quesada, Aurelio and Quaglione, Raffaele and Vaccari, Diego and Garutti, Claudio and Vainer, Lidwien and Kozák, Milan}, article_location = {New York}, article_number = {6}, doi = {http://dx.doi.org/10.1016/j.hrthm.2014.03.011}, keywords = {Cardiac pacing; Managed ventricular pacing; Dual-chamber pacing; Randomized controlled trial; Outcomes}, language = {eng}, issn = {1547-5271}, journal = {Heart Rhythm}, title = {Managed ventricular pacing compared with conventional dual-chamber pacing for elective replacement in chronically paced patients: Results of the Prefer for Elective Replacement Managed Ventricular Pacing randomized study}, volume = {11}, year = {2014} }
TY - JOUR ID - 1231818 AU - Botto, Giovanni L. - Ricci, Renato P. - Benezet, Juan M. - Nielsen, Jens Cosedis - De Roy, Luc - Piot, Olivier - Quesada, Aurelio - Quaglione, Raffaele - Vaccari, Diego - Garutti, Claudio - Vainer, Lidwien - Kozák, Milan PY - 2014 TI - Managed ventricular pacing compared with conventional dual-chamber pacing for elective replacement in chronically paced patients: Results of the Prefer for Elective Replacement Managed Ventricular Pacing randomized study JF - Heart Rhythm VL - 11 IS - 6 SP - 992-1000 EP - 992-1000 PB - Elsevier Science SN - 15475271 KW - Cardiac pacing KW - Managed ventricular pacing KW - Dual-chamber pacing KW - Randomized controlled trial KW - Outcomes N2 - BACKGROUND Several studies have shown that unnecessary right ventricular pacing has detrimental effects. OBJECTIVE To evaluate whether minimization of ventricular pacing as compared with standard dual-chamber pacing (DDD) improves clinical outcomes in patients referred for pacemaker or implantable cardioverter-defibrillator (ICD) replacement. METHODS In an international single-blind, multicenter, randomized controlled trial, we compared DDD with managed ventricular pacing (MVP), a pacing mode developed to minimize ventricular pacing by promoting intrinsic atrioventricular conduction. We included patients referred for device replacement with >40% ventricular pacing, no cardiac resynchronization therapy upgrade indication, no permanent atrial fibrillation (AF), and no permanent complete atrioventricular block. Follow-up was for 2 years. The primary end point was cardiovascular hospitalization. The intention-to-treat analysis was performed by using Kaplan-Meier method and the log-rank test. RESULTS We randomized 605 patients (556 referred for pacemaker and 49 referred for ICD replacement; mean age 75 +/- 11 years; 365 [60%] men, at 7.7 +/- 3.3 years from first device implantation) to MVP (n = 299) or DDD (n = 306). We found no significant differences in the primary end point cardiovascular hospitalization (MVP: 16.3% vs DDD: 14.5 /0; P =.72) and the secondary end point persistent AF (MVP: 15.4% vs DDD: 11.2 /a; P =.08), permanent AF (MVP: 4.1% vs DDD: 3.1%; P =.44), and composite of death and cardiovascular hospitalization (MVP: 23.9% vs DDD: 20.2%; P =.48). MVP reduced right ventricular pacing (median 5% vs 86%; Wilcoxon, P <.0001) as compared with DOD. CONCLUSIONS In patients referred for pacemaker and ICD replacement with clinically well-tolerated long-term exposure to >40% ventricular pacing in the ventricle, a strategy to minimize ventricular pacing is not superior to standard DDD in reducing incidence of cardiovascular hospitalizations. ER -
BOTTO, Giovanni L., Renato P. RICCI, Juan M. BENEZET, Jens Cosedis NIELSEN, Luc DE ROY, Olivier PIOT, Aurelio QUESADA, Raffaele QUAGLIONE, Diego VACCARI, Claudio GARUTTI, Lidwien VAINER and Milan KOZÁK. Managed ventricular pacing compared with conventional dual-chamber pacing for elective replacement in chronically paced patients: Results of the Prefer for Elective Replacement Managed Ventricular Pacing randomized study. \textit{Heart Rhythm}. New York: Elsevier Science, 2014, vol.~11, No~6, p.~992-1000. ISSN~1547-5271. Available from: https://dx.doi.org/10.1016/j.hrthm.2014.03.011.
|