HRDLIČKA, Aleš, Pavel SLAVÍČEK, Magda DVOŘÁKOVÁ, Lukáš NOVOSÁD, Vítězslav OTRUBA a Viktor KANICKÝ. Ionization and excitation effects in plasma pencil spectroscopy. In European Winter Conference on Plasma Spectrochemistry. 2015.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Ionization and excitation effects in plasma pencil spectroscopy
Název česky Ionizační a excitační efekty ve spektroskopii plazmové tužky
Autoři HRDLIČKA, Aleš (203 Česká republika, garant, domácí), Pavel SLAVÍČEK (203 Česká republika, domácí), Magda DVOŘÁKOVÁ (203 Česká republika, domácí), Lukáš NOVOSÁD (203 Česká republika, domácí), Vítězslav OTRUBA (203 Česká republika, domácí) a Viktor KANICKÝ (203 Česká republika, domácí).
Vydání European Winter Conference on Plasma Spectrochemistry, 2015.
Další údaje
Originální jazyk angličtina
Typ výsledku Konferenční abstrakt
Obor 10402 Inorganic and nuclear chemistry
Stát vydavatele Německo
Utajení není předmětem státního či obchodního tajemství
WWW abstrakt přednášky
Kód RIV RIV/00216224:14740/15:00082602
Organizační jednotka Středoevropský technologický institut
Klíčová slova česky spektroskopie; plazmová tužka; snadno ionizovatelné prvky; analýza
Klíčová slova anglicky spectroscopy; plasma pencil; easily ionizable elements; analysis
Příznaky Mezinárodní význam
Změnil Změnil: Mgr. Aleš Hrdlička, Ph.D., učo 22863. Změněno: 26. 3. 2015 08:53.
Anotace
Excitation and ionization effect were studied in a radiofrequency plasma pencil.Element lines with lower excitation energies and lower ionization potential are relatively more intensive near the power electrode while the other lines are more intensive near the ground electrode. Observed decreases of some emission lines in presence of another element evidentially depend on the closeness of the excited levels and ionization limits of the involved atoms. The particular emission profile along the discharge axis can be even adopted from an abundant element to a trace element provided that their energy levels are not very different. In case of a bigger energy gap between the interacting atoms the observed effect of the intensity change is weaker and the axial emission profile remains unchanged. Effects of highly concentrated elements solutions on the excitation and rotational temperatures and electron number density were nearly negligible or weak at a constant forwarded power. Also the plasma stability is still excellent regardless of the amount of introduced sample provided that the amount of water is not increased.
Návaznosti
ED1.1.00/02.0068, projekt VaVNázev: CEITEC - central european institute of technology
ED2.1.00/03.0086, projekt VaVNázev: Regionální VaV centrum pro nízkonákladové plazmové a nanotechnologické povrchové úpravy
VytisknoutZobrazeno: 14. 10. 2024 09:40