AGGARWAL, Niti R., Adéla DROZDOVÁ, Wells J. ASKEW III, Bradley J. KEMP a Panithaya CHAREONTHAITAWEE. Feasibility and diagnostic accuracy of exercise treadmill nitrogen-13 ammonia PET myocardial perfusion imaging of obese patients. Journal of Nuclear Cardiology. New York: Springer, 2015, roč. 22, č. 6, s. 1273-1280. ISSN 1071-3581. Dostupné z: https://dx.doi.org/10.1007/s12350-015-0073-z.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Feasibility and diagnostic accuracy of exercise treadmill nitrogen-13 ammonia PET myocardial perfusion imaging of obese patients
Autoři AGGARWAL, Niti R. (840 Spojené státy), Adéla DROZDOVÁ (203 Česká republika, garant, domácí), Wells J. ASKEW III (840 Spojené státy), Bradley J. KEMP (840 Spojené státy) a Panithaya CHAREONTHAITAWEE (840 Spojené státy).
Vydání Journal of Nuclear Cardiology, New York, Springer, 2015, 1071-3581.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30201 Cardiac and Cardiovascular systems
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 2.929
Kód RIV RIV/00216224:14110/15:00082685
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1007/s12350-015-0073-z
UT WoS 000365303100018
Klíčová slova anglicky Coronary artery disease; exercise stress testing; myocardial perfusion imaging; obesity; positron emission tomography
Štítky EL OK
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Ing. Mgr. Věra Pospíšilíková, učo 9005. Změněno: 30. 12. 2015 14:24.
Anotace
Background. Treadmill exercise nitrogen-13 (13N)-ammonia positron emission tomography (PET) has logistical challenges and limited literature. We aimed to assess its feasibility, image quality, and diagnostic accuracy in obese and nonobese patients. Methods and Results. Between 2009 and 2012, 10,804 patients were referred for myocardial perfusion imaging, including 300 for treadmill PET, of whom 265 were included in this study. Treadmill testing and PET were performed using standard procedures. Image quality, perfusion, and summed stress score (SSS) were assessed. Invasive coronary angiography was performed within 90 days of PET in 43 patients. Mean ± SD body mass index (BMI) was 35.7 ± 7.7 kg/m2 (range 19.5-63.5 kg/m2). Feasibility of treadmill 13N-ammonia PET was 100%. Exercise duration was less for obese patients than nonobese patients (P < .001). Image quality was rated good for 96.9% of obese and 100% of nonobese patients. For all patients, sensitivity was 86.4% and specificity was 74.4%. Diagnostic accuracy did not change significantly with increasing BMI. SSS remained significant in predicting angiographic coronary artery disease after adjustment for age, sex, and Duke treadmill score. Conclusions. Treadmill 13N-ammonia PET is highly feasible, yields good image quality, and has moderately high diagnostic accuracy in a small subset of obese and nonobese patients who are deemed able to perform treadmill exercise.