FARKA, Zdeněk, David KOVÁŘ a Petr SKLÁDAL. Quartz crystal microbalance biosensor for rapid detection of aerosolized microorganisms. Online. In Augustus Way Fountain. Proc. SPIE 9455, Chemical, Biological, Radiological, Nuclear, and Explosives (CBRNE) Sensing XVI. USA: SPIE, 2015, s. 1-9. ISBN 978-1-62841-571-1. Dostupné z: https://dx.doi.org/10.1117/12.2084606.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Quartz crystal microbalance biosensor for rapid detection of aerosolized microorganisms
Autoři FARKA, Zdeněk (203 Česká republika, domácí), David KOVÁŘ (203 Česká republika, domácí) a Petr SKLÁDAL (203 Česká republika, garant, domácí).
Vydání USA, Proc. SPIE 9455, Chemical, Biological, Radiological, Nuclear, and Explosives (CBRNE) Sensing XVI, od s. 1-9, 9 s. 2015.
Nakladatel SPIE
Další údaje
Originální jazyk angličtina
Typ výsledku Stať ve sborníku
Obor 10600 1.6 Biological sciences
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
Forma vydání elektronická verze "online"
WWW URL
Kód RIV RIV/00216224:14740/15:00082954
Organizační jednotka Středoevropský technologický institut
ISBN 978-1-62841-571-1
ISSN 0277-786X
Doi http://dx.doi.org/10.1117/12.2084606
UT WoS 000357744700006
Klíčová slova anglicky Biosensor; Cyclone sampling; Quartz crystal microbalance; Bioaerosol; Escherichia coli
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnil: doc. Mgr. Zdeněk Farka, Ph.D., učo 357740. Změněno: 11. 8. 2015 08:59.
Anotace
Biological warfare agents (BWAs) represent the current menace of the asymmetric war. The early detection of BWAs, especially in the form of bioaerosol, is a challenging task for governments all around the world. Label-free quartz crystal microbalance (QCM) immunosensor and electrochemical immunosensor were developed and tested for rapid detection of BWA surrogate (E. coli) in the form of bioaerosol. Two immobilization strategies for the attachment of antibody were tested; the gold sensor surface was activated by cysteamine and then antibody was covalently linked either using glutaraldehyde, or the reduced antibodies were attached via Sulfo-SMCC. A portable bioaerosol chamber was constructed and used for safe manipulation with aerosolized microorganisms. The dissemination was done using a piezoelectric humidifier, distribution of bioaerosol inside the chamber was ensured using three 12-cm fans. The whole system was controlled remotely using LAN network. The disseminated microbial cells were collected and preconcentrated using the wetted-wall cyclone SASS 2300, the analysis was done using the on-line linked immunosensors. The QCM immunosensor had limit of detection 1×10^4 CFU·L-1 of air with analysis time 16 min, the whole experiment including dissemination and sensor surface regeneration took 40 min. In case of blank (disseminated sterile buffer), no signal change was observed. The electrochemical immunosensor was able to detect 150 CFU·L-1 of air in 20 min; also in this case, no interferences were observed. Reference measurements were done using particle counter Met One 3400 and by cultivation method on agar plates. The sensors have proved to be applicable for rapid screening of microorganisms in air.