GREGUŠ, Michal, František FORET, Dagmar KINDLOVÁ, Eva POKOJOVÁ, Marek PLUTINSKÝ, Martina DOUBKOVÁ, Zdeněk MERTA, Ilona BINKOVÁ, Jana SKŘIČKOVÁ a Petr KUBÁŇ. Monitoring the ionic content of exhaled breath condensate in various respiratory diseases by capillary electrophoresis with contactless conductivity detection. JOURNAL OF BREATH RESEARCH. BRISTOL: IOP PUBLISHING LTD, 2015, roč. 9, č. 2, s. nestránkováno, 10 s. ISSN 1752-7155. Dostupné z: https://dx.doi.org/10.1088/1752-7155/9/2/027107.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Monitoring the ionic content of exhaled breath condensate in various respiratory diseases by capillary electrophoresis with contactless conductivity detection
Autoři GREGUŠ, Michal (703 Slovensko, domácí), František FORET (203 Česká republika, domácí), Dagmar KINDLOVÁ (203 Česká republika), Eva POKOJOVÁ (203 Česká republika), Marek PLUTINSKÝ (703 Slovensko, domácí), Martina DOUBKOVÁ (203 Česká republika, domácí), Zdeněk MERTA (203 Česká republika, domácí), Ilona BINKOVÁ (203 Česká republika), Jana SKŘIČKOVÁ (203 Česká republika, domácí) a Petr KUBÁŇ (203 Česká republika, garant, domácí).
Vydání JOURNAL OF BREATH RESEARCH, BRISTOL, IOP PUBLISHING LTD, 2015, 1752-7155.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 4.177
Kód RIV RIV/00216224:14740/15:00080937
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1088/1752-7155/9/2/027107
UT WoS 000355656200015
Klíčová slova anglicky exhaled breath condensate; capillary electrophoresis; contactless conductivity detection; anions and cations; respiratory diseases
Štítky EL OK, podil, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Olga Křížová, učo 56639. Změněno: 26. 4. 2016 11:45.
Anotace
The analysis of an ionic profile of exhaled breath condensate (EBC) by capillary electrophoresis with contactless conductivity detection and double opposite end injection, is demonstrated. A miniature sampler made from a 2 ml syringe and an aluminium cooling cylinder was used for the fast collection of EBC (under one minute). Analysis of the collected EBC was performed in a 60 mM 2-(N-morpholino) ethanesulfonic acid, 60 mM L-histidine background electrolyte with 30 mu M cetyltrimethylammonium bromide and 2 mM 18-crown-6 at pH 6, and excellent repeatability of migration times (RSD < 1.3% (n = 7)) and peak areas (RSD < 7% (n = 7)) of 14 ions (inorganic anions, cations and organic acids) was obtained. It is demonstrated that the analysis of EBC samples obtained from patients with various respiratory diseases (chronic obstructive pulmonary disease, asthma, pulmonary fibrosis, sarcoidosis, cystic fibrosis) is possible in less than five minutes and the ionic profile can be compared with the group of healthy individuals. The analysis of the ionic profile of EBC samples provides a set of data in which statistically significant differences among the groups of patients could be observed for several clinically relevant anions (nitrite, nitrate, acetate, lactate). The developed collection system and method provides a highly reproducible and fast way of collecting and analyzing EBC, with future applicability in point-of-care diagnostics.
Návaznosti
ED1.1.00/02.0068, projekt VaVNázev: CEITEC - central european institute of technology
GA13-21919S, projekt VaVNázev: Vývoj neinvazivních metod odběru vzorků a analýzy v point-of-care dignostice biologických materiálů.
Investor: Grantová agentura ČR, Vývoj neinvazivních metod odberu vzorku a analýzy v point-of-care dignostice biologických materiálu