J 2015

Monitoring the ionic content of exhaled breath condensate in various respiratory diseases by capillary electrophoresis with contactless conductivity detection

GREGUŠ, Michal, František FORET, Dagmar KINDLOVÁ, Eva POKOJOVÁ, Marek PLUTINSKÝ et. al.

Základní údaje

Originální název

Monitoring the ionic content of exhaled breath condensate in various respiratory diseases by capillary electrophoresis with contactless conductivity detection

Autoři

GREGUŠ, Michal (703 Slovensko, domácí), František FORET (203 Česká republika, domácí), Dagmar KINDLOVÁ (203 Česká republika), Eva POKOJOVÁ (203 Česká republika), Marek PLUTINSKÝ (703 Slovensko, domácí), Martina DOUBKOVÁ (203 Česká republika, domácí), Zdeněk MERTA (203 Česká republika, domácí), Ilona BINKOVÁ (203 Česká republika), Jana SKŘIČKOVÁ (203 Česká republika, domácí) a Petr KUBÁŇ (203 Česká republika, garant, domácí)

Vydání

JOURNAL OF BREATH RESEARCH, BRISTOL, IOP PUBLISHING LTD, 2015, 1752-7155

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

10406 Analytical chemistry

Stát vydavatele

Velká Británie a Severní Irsko

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 4.177

Kód RIV

RIV/00216224:14740/15:00080937

Organizační jednotka

Středoevropský technologický institut

UT WoS

000355656200015

Klíčová slova anglicky

exhaled breath condensate; capillary electrophoresis; contactless conductivity detection; anions and cations; respiratory diseases

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 26. 4. 2016 11:45, Olga Křížová

Anotace

V originále

The analysis of an ionic profile of exhaled breath condensate (EBC) by capillary electrophoresis with contactless conductivity detection and double opposite end injection, is demonstrated. A miniature sampler made from a 2 ml syringe and an aluminium cooling cylinder was used for the fast collection of EBC (under one minute). Analysis of the collected EBC was performed in a 60 mM 2-(N-morpholino) ethanesulfonic acid, 60 mM L-histidine background electrolyte with 30 mu M cetyltrimethylammonium bromide and 2 mM 18-crown-6 at pH 6, and excellent repeatability of migration times (RSD < 1.3% (n = 7)) and peak areas (RSD < 7% (n = 7)) of 14 ions (inorganic anions, cations and organic acids) was obtained. It is demonstrated that the analysis of EBC samples obtained from patients with various respiratory diseases (chronic obstructive pulmonary disease, asthma, pulmonary fibrosis, sarcoidosis, cystic fibrosis) is possible in less than five minutes and the ionic profile can be compared with the group of healthy individuals. The analysis of the ionic profile of EBC samples provides a set of data in which statistically significant differences among the groups of patients could be observed for several clinically relevant anions (nitrite, nitrate, acetate, lactate). The developed collection system and method provides a highly reproducible and fast way of collecting and analyzing EBC, with future applicability in point-of-care diagnostics.

Návaznosti

ED1.1.00/02.0068, projekt VaV
Název: CEITEC - central european institute of technology
GA13-21919S, projekt VaV
Název: Vývoj neinvazivních metod odběru vzorků a analýzy v point-of-care dignostice biologických materiálů.
Investor: Grantová agentura ČR, Vývoj neinvazivních metod odberu vzorku a analýzy v point-of-care dignostice biologických materiálu

Přiložené soubory

ZVV_1307054_Monitoring_the_ionic.pdf
Požádat o autorskou verzi souboru