GREGUŠ, Michal, František FORET, Dagmar KINDLOVÁ, Eva POKOJOVÁ, Marek PLUTINSKÝ et. al.Základní údaje
Originální název
Monitoring the ionic content of exhaled breath condensate in various respiratory diseases by capillary electrophoresis with contactless conductivity detection
Autoři
GREGUŠ, Michal (703 Slovensko, domácí), František FORET (203 Česká republika, domácí), Dagmar KINDLOVÁ (203 Česká republika), Eva POKOJOVÁ (203 Česká republika), Marek PLUTINSKÝ (703 Slovensko, domácí), Martina DOUBKOVÁ (203 Česká republika, domácí), Zdeněk MERTA (203 Česká republika, domácí), Ilona BINKOVÁ (203 Česká republika), Jana SKŘIČKOVÁ (203 Česká republika, domácí) a Petr KUBÁŇ (203 Česká republika, garant, domácí)
Vydání
JOURNAL OF BREATH RESEARCH, BRISTOL, IOP PUBLISHING LTD, 2015, 1752-7155
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10406 Analytical chemistry
Stát vydavatele
Velká Británie a Severní Irsko
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 4.177
Kód RIV
RIV/00216224:14740/15:00080937
Organizační jednotka
Středoevropský technologický institut
UT WoS
000355656200015
Klíčová slova anglicky
exhaled breath condensate; capillary electrophoresis; contactless conductivity detection; anions and cations; respiratory diseases
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 26. 4. 2016 11:45, Olga Křížová
Anotace
V originále
The analysis of an ionic profile of exhaled breath condensate (EBC) by capillary electrophoresis with contactless conductivity detection and double opposite end injection, is demonstrated. A miniature sampler made from a 2 ml syringe and an aluminium cooling cylinder was used for the fast collection of EBC (under one minute). Analysis of the collected EBC was performed in a 60 mM 2-(N-morpholino) ethanesulfonic acid, 60 mM L-histidine background electrolyte with 30 mu M cetyltrimethylammonium bromide and 2 mM 18-crown-6 at pH 6, and excellent repeatability of migration times (RSD < 1.3% (n = 7)) and peak areas (RSD < 7% (n = 7)) of 14 ions (inorganic anions, cations and organic acids) was obtained. It is demonstrated that the analysis of EBC samples obtained from patients with various respiratory diseases (chronic obstructive pulmonary disease, asthma, pulmonary fibrosis, sarcoidosis, cystic fibrosis) is possible in less than five minutes and the ionic profile can be compared with the group of healthy individuals. The analysis of the ionic profile of EBC samples provides a set of data in which statistically significant differences among the groups of patients could be observed for several clinically relevant anions (nitrite, nitrate, acetate, lactate). The developed collection system and method provides a highly reproducible and fast way of collecting and analyzing EBC, with future applicability in point-of-care diagnostics.