KOK, Madeleine, Jakub TUREK, Casper MIHL, Sebastian D. REINARTZ, Robin F. GOHMANN, Estelle C. NIJSSEN, Suzanne KATS, Vincent G. van OMMEN, Bas L.J.H. KIETSELAER, Joachim E. WILDBERGER a Marco DAS. Low contrast media volume in pre-TAVI CT examinations. European Radiology. New York: Springer, 2016, roč. 26, č. 8, s. 2426-2435. ISSN 0938-7994. Dostupné z: https://dx.doi.org/10.1007/s00330-015-4080-x.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Low contrast media volume in pre-TAVI CT examinations
Autoři KOK, Madeleine (528 Nizozemské království), Jakub TUREK (703 Slovensko, garant, domácí), Casper MIHL (528 Nizozemské království), Sebastian D. REINARTZ (276 Německo), Robin F. GOHMANN (276 Německo), Estelle C. NIJSSEN (528 Nizozemské království), Suzanne KATS (528 Nizozemské království), Vincent G. van OMMEN (528 Nizozemské království), Bas L.J.H. KIETSELAER (528 Nizozemské království), Joachim E. WILDBERGER (528 Nizozemské království) a Marco DAS (528 Nizozemské království).
Vydání European Radiology, New York, Springer, 2016, 0938-7994.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30000 3. Medical and Health Sciences
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 3.967
Kód RIV RIV/00216224:14110/16:00089238
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1007/s00330-015-4080-x
UT WoS 000379192500002
Klíčová slova anglicky Transcatheter aortic valve implantation; Multi detector-row CT; Contrast media; Diagnostic imaging; Contrast induced nephropathy
Štítky EL OK
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Ing. Mgr. Věra Pospíšilíková, učo 9005. Změněno: 25. 8. 2016 12:09.
Anotace
To evaluate image quality using reduced contrast media (CM) volume in pre-TAVI assessment. Forty-seven consecutive patients referred for pre-TAVI examination were evaluated. Patients were divided into two groups: group 1 BMI < 28 kg/m(2) (n = 29); and group 2 BMI > 28 kg/m(2) (n = 18). Patients received a combined scan protocol: retrospective ECG-gated helical CTA of the aortic root (80kVp) followed by a high-pitch spiral CTA (group 1: 70 kV; group 2: 80 kVp) from aortic arch to femoral arteries. All patients received one bolus of CM (300 mgI/ml): group 1: volume = 40 ml; flow rate = 3 ml/s, group 2: volume = 53 ml; flow rate = 4 ml/s. Attenuation values (HU) and contrast-to-noise ratio (CNR) were measured at the levels of the aortic root (helical) and peripheral arteries (high-pitch). Diagnostic image quality was considered sufficient at attenuation values > 250HU and CNR > 10. Diagnostic image quality for TAVI measurements was obtained in 46 patients. Mean attenuation values and CNR (HU +/- SD) at the aortic root (helical) were: group 1: 381 +/- 65HU and 13 +/- 8; group 2: 442 +/- 68HU and 10 +/- 5. At the peripheral arteries (high-pitch), mean values were: group 1: 430 +/- 117HU and 11 +/- 6; group 2: 389 +/- 102HU and 13 +/- 6. CM volume can be substantially reduced using low kVp protocols, while maintaining sufficient image quality for the evaluation of aortic root and peripheral access sites. Image quality could be maintained using low kVp scan protocols. Low kVp protocols reduce contrast media volume by 34-67 %. Less contrast media volume lowers the risk of contrast-induced nephropathy.