GREGUŠ, Michal, František FORET a Petr KUBÁŇ. Single-breath analysis using a novel simple sampler and capillary electrophoresis with contactless conductometric detection. Electrophoresis. HOBOKEN: WILEY-BLACKWELL, 2015, roč. 36, č. 4, s. 526-533. ISSN 0173-0835. Dostupné z: https://dx.doi.org/10.1002/elps.201400456.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Single-breath analysis using a novel simple sampler and capillary electrophoresis with contactless conductometric detection
Autoři GREGUŠ, Michal (703 Slovensko, domácí), František FORET (203 Česká republika, garant, domácí) a Petr KUBÁŇ (203 Česká republika, domácí).
Vydání Electrophoresis, HOBOKEN, WILEY-BLACKWELL, 2015, 0173-0835.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.482
Kód RIV RIV/00216224:14740/15:00081636
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1002/elps.201400456
UT WoS 000349969700006
Klíčová slova anglicky Anions; Capillary electrophoresis; Cations; Contactless conductivity detection; Exhaled breath condensate; Single-breath analysis
Štítky podil, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Eva Špillingová, učo 110713. Změněno: 5. 4. 2016 16:55.
Anotace
The analysis of ionic content of exhaled breath condensate (EBC) from one single breath by CE with (CD)-D-4 is demonstrated for the first time. A miniature sampler made from a 2-mL syringe and an aluminum cooling cylinder for collection of EBC was developed. Various parameters of the sampler that influence its collection efficiency, repeatability, and effect of respiratory patterns were studied in detail. Efficient procedures for the cleanup of the miniature sampler were also developed and resulted in significant improvement of sampling repeatability. Analysis of EBC was performed by CE-(CD)-D-4 in a 60 mM MES/L-histidine BGE with 30 mu M CTAB and 2 mM 18-crown-6 at pH 6 and excellent repeatability of migration times (RSD < 1.3% (n = 7)) and peak areas (RSD < 7% (n = 7)) of 12 inorganic anions, cations, and organic acids was obtained. It has been shown that the breathing pattern has a significant impact on the concentration of the analytes in the collected EBC. As the ventilatory pattern can be easily controlled during single exhalation, the developed collection system and method provides a highly reproducible and fast way of collecting EBC with applicability in point-of-care diagnostics.
Návaznosti
ED1.1.00/02.0068, projekt VaVNázev: CEITEC - central european institute of technology
GA13-21919S, projekt VaVNázev: Vývoj neinvazivních metod odběru vzorků a analýzy v point-of-care dignostice biologických materiálů.
Investor: Grantová agentura ČR, Vývoj neinvazivních metod odberu vzorku a analýzy v point-of-care dignostice biologických materiálu
VytisknoutZobrazeno: 26. 4. 2024 21:42