VACULOVIČ, Tomáš, Tereza WARCHILOVÁ, Zuzana ČADKOVÁ, Jiřina SZÁKOVÁ, Pavel TLUSTOŠ, Vítězslav OTRUBA a Viktor KANICKÝ. Influence of laser ablation parameters on trueness of imaging. Applied Surface Science. Amsterdam: Elsevier Science, 2015, roč. 351, October, s. 296-302. ISSN 0169-4332. Dostupné z: https://dx.doi.org/10.1016/j.apsusc.2015.05.136.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Influence of laser ablation parameters on trueness of imaging
Autoři VACULOVIČ, Tomáš (203 Česká republika, garant, domácí), Tereza WARCHILOVÁ (203 Česká republika, domácí), Zuzana ČADKOVÁ (203 Česká republika), Jiřina SZÁKOVÁ (203 Česká republika), Pavel TLUSTOŠ (203 Česká republika), Vítězslav OTRUBA (203 Česká republika, domácí) a Viktor KANICKÝ (203 Česká republika, domácí).
Vydání Applied Surface Science, Amsterdam, Elsevier Science, 2015, 0169-4332.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 3.150
Kód RIV RIV/00216224:14740/15:00081675
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1016/j.apsusc.2015.05.136
UT WoS 000359496600038
Klíčová slova anglicky laser ablation; ICP-MS; imaging; tapeworm
Štítky rivok
Změnil Změnila: Mgr. Eva Špillingová, učo 110713. Změněno: 12. 4. 2016 12:47.
Anotace
Influence of laser ablation conditions on limit of detection, spatial resolution and time of analysis was studied for laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) applied to elemental mapping. Laser repetition rate and laser fluence were investigated in tapeworm thin section to attain optimum ablation rate yielding appropriately low detection limit which complies with elemental contents in the tissue. Effect of combinations of laser spot size and scan speed on relative broadening (wrel) of image of the ablated pattern (line) was investigated with the aim to quantify the trueness of imaging. Ink lines printed on paper were employed for the study of influence of spot size and scan speed on limit of detection, relative broadening of elemental image and duration of elemental mapping. An uneven distribution of copper in a printed line (coffee stain effect) was observed. The wrel is strongly reduced (down to 2 %) at low scan speed (10 um s-1) and laser spot diameter of 10 um but with resulting unacceptably long time of mapping (up to 3000 min). Finally, tapeworm thin section elemental maps (4 mm x 5 mm) were obtained at the laser spot diameter of 65 um and the scan speed of 65 um s-1 within 100 minutes. A dissimilar lateral distribution of Pb was observed in comparison with that of Cu or Zn due to different pathways of element uptake.