VRANA, Branislav, Lucie KOMANCOVÁ a Jaromír SOBOTKA. Calibration of a passive sampler based on stir bar sorptive extraction for the monitoring of hydrophobic organic pollutants in water. Talanta. AMSTERDAM: Elsevier, 2016, roč. 152, May, s. 90-97. ISSN 0039-9140. Dostupné z: https://dx.doi.org/10.1016/j.talanta.2016.01.040.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Calibration of a passive sampler based on stir bar sorptive extraction for the monitoring of hydrophobic organic pollutants in water
Autoři VRANA, Branislav (703 Slovensko, garant, domácí), Lucie KOMANCOVÁ (203 Česká republika, domácí) a Jaromír SOBOTKA (203 Česká republika, domácí).
Vydání Talanta, AMSTERDAM, Elsevier, 2016, 0039-9140.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Nizozemské království
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 4.162
Kód RIV RIV/00216224:14310/16:00089980
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1016/j.talanta.2016.01.040
UT WoS 000373651000011
Klíčová slova anglicky Stir bar sorptive extraction; Passive dosing; Passive sampling; Polydimethylsiloxane; Priority organic pollutants; Water monitoring
Štítky AKR, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Marie Šípková, DiS., učo 437722. Změněno: 13. 3. 2020 11:22.
Anotace
A passive sampler based on stir bars coated with polydimethylsiloxane (PDMS) was calibrated for the measurement of time-weighted average concentrations of hydrophobic micropollutants, including polycyclic aromatic hydrocarbons, polychlorinated biphenyls and organochlorine pesticides, in water. Stir bar/water partition coefficients were measured by equilibrating bars with sheets made of silicone rubber material for which partition coefficients had been reported previously. Kinetic parameters characterising the exchange of analytes between stir bars and water were determined under controlled exposure conditions using a passive dosing system. The dosing system consisted of silicone rubber sheets with a large surface area, spiked with analytes. During stir bar sampler exposure, analytes partitioned from dosing sheets to water in the exposure tank and maintained constant exposure concentrations. Reversible and isotropic exchange kinetics of analytes between sampler and water was confirmed by measuring the release of a range of performance reference compounds (PRCs) from stir bars. Application of a two-resistance model confirmed that, except for hexachlorocyclohexane isomers, uptake of the test compounds under the experimental conditions was controlled by diffusion in the water boundary layer. This permits the application of PRCs for in situ calibration of uptake kinetics of test compounds to stir bars.
Návaznosti
LM2011028, projekt VaVNázev: RECETOX ? Národní infrastruktura pro výzkum toxických látek v prostředí
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, RECETOX Národní infrastruktura pro výzkum toxických látek v prostředí
LO1214, projekt VaVNázev: Centrum pro výzkum toxických látek v prostředí (Akronym: RECETOX)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Centrum pro výzkum toxických látek v prostředí
603437, interní kód MUNázev: SOLUTIONS - Solutions for present and future emerging pollutants in land and water resources management (Akronym: SOLUTIONS)
Investor: Evropská unie, SOLUTIONS - Solutions for present and future emerging pollutants in land and water resources management, Spolupráce
VytisknoutZobrazeno: 5. 5. 2024 20:12