J 2016

Calibration of a passive sampler based on stir bar sorptive extraction for the monitoring of hydrophobic organic pollutants in water

VRANA, Branislav, Lucie KOMANCOVÁ a Jaromír SOBOTKA

Základní údaje

Originální název

Calibration of a passive sampler based on stir bar sorptive extraction for the monitoring of hydrophobic organic pollutants in water

Autoři

VRANA, Branislav (703 Slovensko, garant, domácí), Lucie KOMANCOVÁ (203 Česká republika, domácí) a Jaromír SOBOTKA (203 Česká republika, domácí)

Vydání

Talanta, AMSTERDAM, Elsevier, 2016, 0039-9140

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

10406 Analytical chemistry

Stát vydavatele

Nizozemské království

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 4.162

Kód RIV

RIV/00216224:14310/16:00089980

Organizační jednotka

Přírodovědecká fakulta

UT WoS

000373651000011

Klíčová slova anglicky

Stir bar sorptive extraction; Passive dosing; Passive sampling; Polydimethylsiloxane; Priority organic pollutants; Water monitoring

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 13. 3. 2020 11:22, Mgr. Marie Šípková, DiS.

Anotace

V originále

A passive sampler based on stir bars coated with polydimethylsiloxane (PDMS) was calibrated for the measurement of time-weighted average concentrations of hydrophobic micropollutants, including polycyclic aromatic hydrocarbons, polychlorinated biphenyls and organochlorine pesticides, in water. Stir bar/water partition coefficients were measured by equilibrating bars with sheets made of silicone rubber material for which partition coefficients had been reported previously. Kinetic parameters characterising the exchange of analytes between stir bars and water were determined under controlled exposure conditions using a passive dosing system. The dosing system consisted of silicone rubber sheets with a large surface area, spiked with analytes. During stir bar sampler exposure, analytes partitioned from dosing sheets to water in the exposure tank and maintained constant exposure concentrations. Reversible and isotropic exchange kinetics of analytes between sampler and water was confirmed by measuring the release of a range of performance reference compounds (PRCs) from stir bars. Application of a two-resistance model confirmed that, except for hexachlorocyclohexane isomers, uptake of the test compounds under the experimental conditions was controlled by diffusion in the water boundary layer. This permits the application of PRCs for in situ calibration of uptake kinetics of test compounds to stir bars.

Návaznosti

LM2011028, projekt VaV
Název: RECETOX ? Národní infrastruktura pro výzkum toxických látek v prostředí
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, RECETOX Národní infrastruktura pro výzkum toxických látek v prostředí
LO1214, projekt VaV
Název: Centrum pro výzkum toxických látek v prostředí (Akronym: RECETOX)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Centrum pro výzkum toxických látek v prostředí
603437, interní kód MU
Název: SOLUTIONS - Solutions for present and future emerging pollutants in land and water resources management (Akronym: SOLUTIONS)
Investor: Evropská unie, SOLUTIONS - Solutions for present and future emerging pollutants in land and water resources management, Spolupráce