HORŇÁKOVÁ, Veronika, Jan PŘIBYL a Petr SKLÁDAL. Study of DNA immobilization on mica surface by atomic force microscopy. Monatshefte fur Chemie. Wien: Springer Wien, 2016, roč. 147, č. 5, s. 865-871. ISSN 0026-9247. Dostupné z: https://dx.doi.org/10.1007/s00706-016-1695-9.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Study of DNA immobilization on mica surface by atomic force microscopy
Autoři HORŇÁKOVÁ, Veronika (203 Česká republika, domácí), Jan PŘIBYL (203 Česká republika, domácí) a Petr SKLÁDAL (203 Česká republika, garant, domácí).
Vydání Monatshefte fur Chemie, Wien, Springer Wien, 2016, 0026-9247.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10600 1.6 Biological sciences
Stát vydavatele Rakousko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 1.282
Kód RIV RIV/00216224:14740/16:00090063
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1007/s00706-016-1695-9
UT WoS 000374172200004
Klíčová slova anglicky Atomic force microscopy; DNA; Nanostructures; Silanization; Cations; Ethanolamine
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Eva Špillingová, učo 110713. Změněno: 22. 2. 2017 12:54.
Anotace
Since its discovery, atomic force microscopy (AFM) is widely used to study biological objects and materials, including cells, proteins, and nucleic acids. AFM measurements are carried out in the air as well as in liquid with a very high resolution, even more complex bioprocesses can be monitored in situ under physiological conditions. Successful imaging of DNA molecules on the flat supporting surface typically requires appropriate treatment of mica. The original surface charge of mica is the same as of DNA, i.e. negative. Accordingly, immobilization using bivalent cations (Mg2+, Ni2+, and Co2+), deposition of ethanolamine, and mica surface silanization with alkoxysiloxane derivatives were reported to achieve an optimal concentration and surface arrangement of DNA molecules. Vapours of alkoxysiloxane derivatives led to uniform negatively charged mica surface and it was found that higher ionic radius causes a weaker bond. A better quality and sharper images of DNA molecules were achieved by adjusting the correct real amplitude of the cantilever. This amplitude should correspond with the expected size of the target objects-DNA molecules in the x-y plane of the image. The length of the observed DNA molecules was 1000 bp and the planar width of DNA was 7.8 nm (in reality 3 nm). The AFM spectroscopic mode was particularly useful.
Návaznosti
ED1.1.00/02.0068, projekt VaVNázev: CEITEC - central european institute of technology
VytisknoutZobrazeno: 27. 4. 2024 04:21