HLAVÁČEK, Antonín, Zdeněk FARKA, Maria HUEBNER, Veronika HORŇÁKOVÁ, Daniel NĚMEČEK, Reinhard NIESSNER, Petr SKLÁDAL, Dietmar KNOPP a Hans Heiner GORRIS. Competitive Upconversion-Linked Immunosorbent Assay for the Sensitive Detection of Diclofenac. Analytical Chemistry. Washington, D.C., USA: American Chemical Society, 2016, roč. 88, č. 11, s. 6011-6017. ISSN 0003-2700. Dostupné z: https://dx.doi.org/10.1021/acs.analchem.6b01083.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Competitive Upconversion-Linked Immunosorbent Assay for the Sensitive Detection of Diclofenac
Autoři HLAVÁČEK, Antonín (203 Česká republika, domácí), Zdeněk FARKA (203 Česká republika, domácí), Maria HUEBNER (276 Německo), Veronika HORŇÁKOVÁ (203 Česká republika, domácí), Daniel NĚMEČEK (203 Česká republika, domácí), Reinhard NIESSNER (276 Německo), Petr SKLÁDAL (203 Česká republika, garant, domácí), Dietmar KNOPP (276 Německo) a Hans Heiner GORRIS (276 Německo).
Vydání Analytical Chemistry, Washington, D.C., USA, American Chemical Society, 2016, 0003-2700.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 6.320
Kód RIV RIV/00216224:14740/16:00090133
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1021/acs.analchem.6b01083
UT WoS 000377631000065
Klíčová slova anglicky antibody; bioconjugation; diclofenac; immunoassay; pharmaceutical micropollutant; photon-upconversion
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnil: doc. Mgr. Zdeněk Farka, Ph.D., učo 357740. Změněno: 15. 9. 2018 18:49.
Anotace
Photon-upconverting nanoparticles (UCNPs) emit light of shorter wavelength under near-infrared excitation and thus avoid optical background interference. We have exploited this unique photophysical feature to establish a sensitive competitive immunoassay for the detection of the pharmaceutical micropollutant diclofenac (DCF) in water. The so-called upconversion-linked immunosorbent assay (ULISA) was critically dependent on the design of the upconversion luminescent detection label. Silica-coated UCNPs (50 nm in diameter) exposing carboxyl groups on the surface were conjugated to a secondary anti-IgG antibody. We investigated the structure and monodispersity of the nanoconjugates in detail. Using a highly affine anti-DCF primary antibody, the optimized ULISA reached a detection limit of 0.05 ng DCF per mL. This performance came close to a conventional enzyme-linked immunosorbent assay (ELISA) without the need for an enzyme-mediated signal amplification step. The ULISA was further employed for analyzing drinking and surface water samples. The results were consistent with a conventional ELISA as well as liquid chromatography–mass spectrometry (LC–MS).
Návaznosti
ED1.1.00/02.0068, projekt VaVNázev: CEITEC - central european institute of technology
EE2.3.30.0009, projekt VaVNázev: Zaměstnáním čerstvých absolventů doktorského studia k vědecké excelenci
LD15023, projekt VaVNázev: Příprava diskrétních biokonjugátů photon-upconversion nanočástic
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Příprava diskrétních biokonjugátů photon-upconversion nanočástic
VytisknoutZobrazeno: 28. 7. 2024 16:52