J 2016

Electrochemical determination of adenine using a glassy carbon electrode modified with graphene oxide and polyaniline

SHARMA, Vimal Kumar, David HYNEK, Libuše TRNKOVÁ, Dušan HEMZAL, Marian MÁRIK et. al.

Základní údaje

Originální název

Electrochemical determination of adenine using a glassy carbon electrode modified with graphene oxide and polyaniline

Autoři

SHARMA, Vimal Kumar (356 Indie, domácí), David HYNEK (203 Česká republika), Libuše TRNKOVÁ (203 Česká republika, garant, domácí), Dušan HEMZAL (203 Česká republika, domácí), Marian MÁRIK (703 Slovensko), René KIZEK (203 Česká republika) a Jaromír HUBÁLEK (203 Česká republika)

Vydání

Microchimica Acta, Wien, Springer-Verlag, 2016, 0026-3672

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

10403 Physical chemistry

Stát vydavatele

Rakousko

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 4.580

Kód RIV

RIV/00216224:14310/16:00090238

Organizační jednotka

Přírodovědecká fakulta

UT WoS

000373146100003

Klíčová slova česky

nanokompozit; senzor; cyklická voltametrie; diferenční pulzní voltametrie; skenovací elektronová mikroskopie; Ramanova spektroskopie

Klíčová slova anglicky

nanocomposite; sensor; cyclic voltammetry; differential pulse voltammetry; scanning electron microscopy; Raman spectroscopy

Štítky

Změněno: 23. 4. 2020 17:40, Mgr. Marie Šípková, DiS.

Anotace

V originále

The electrochemical behavior of adenine at a glassy carbon electrode (GCE) modified with a nanocomposite consisting of graphene oxide and polyaniline was investigated by cyclic voltammetry and differential pulse voltammetry. The nanocomposite was synthesized by polymerization and characterized by Raman and UV-vis spectroscopy, and its morphology was examined by scanning electron microscopy. Adenine is oxidized at the modified GCE at a working potential of 1.2 V (vs. Ag/AgCl) and gives a current density of approximately 2.64 nA.cm(-2), which is distinctly increased compared to the 0.57 nA.cm(-2) of a bare electrode. Peak current and adenine concentration are linearly related to each other in the range from 0.5 mu M to 20 mu M. The modified GCE exhibits acceptable analytical performance, with a detection limit of 72 nM and a limit of quantification of 240 nM. It is excellently reproducible, stable, and fabrication is simple.

Návaznosti

EE2.3.30.0009, projekt VaV
Název: Zaměstnáním čerstvých absolventů doktorského studia k vědecké excelenci
LH13053, projekt VaV
Název: Chemická a elektrochemická analýza purinových derivátů a jejich komplexů s mědí (Akronym: CECAP)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Chemická a elektrochemická analýza purinových derivátů