FARKA, Zdeněk, Tomáš JUŘÍK, Pavel PODEŠVA, David KOVÁŘ, František FORET a Petr SKLÁDAL. Gelatin-templated Nanostructured Gold for Electrochemical Detection of Glucose in Serum. In 67th Annual Meeting of the International Society of Electrochemistry. 2016.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Gelatin-templated Nanostructured Gold for Electrochemical Detection of Glucose in Serum
Autoři FARKA, Zdeněk, Tomáš JUŘÍK, Pavel PODEŠVA, David KOVÁŘ, František FORET a Petr SKLÁDAL.
Vydání 67th Annual Meeting of the International Society of Electrochemistry, 2016.
Další údaje
Originální jazyk angličtina
Typ výsledku Konferenční abstrakt
Obor 10405 Electrochemistry
Stát vydavatele Nizozemské království
Utajení není předmětem státního či obchodního tajemství
WWW URL
Organizační jednotka Středoevropský technologický institut
Klíčová slova anglicky Gold nanostructures; Gelatin template; Glucose electrooxidation; Non-enzymatic sensor; Blood analysis
Příznaky Mezinárodní význam
Změnil Změnil: doc. Mgr. Zdeněk Farka, Ph.D., učo 357740. Změněno: 30. 8. 2016 15:48.
Anotace
Nanostructured electrodes based on gelatin-templated gold were developed for sensitive non-enzymatic detection of glucose. The structures of specific saw tooth-like morphology were formed by electrodeposition of gold through the cavities of crosslinked gelatin. The growth of nanostructures was investigated by scanning electron microscopy (SEM) and atomic force microscopy (AFM). The electroactive surface area (ESA) and electrochemical behavior of the prepared electrodes were determined by the cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The roughness factor (expressed as ESA divided by geometrical area) of the gelatin-templated surface was estimated to be 16.7, which represent 15.9 fold enlargement compared to the flat gold electrode. The nanoscopic surface exhibited strong electrocatalytic effect towards glucose oxidation. The detection of glucose was done by direct electrochemical oxidation during CV and amperometry. In case of CV, the sensitivity of 1165 μA·mM-1·cm-2, wide linear range from 32 μM to 10 mM and limit of detection (LOD) of 90 μM were achieved. The amperometry allowed to further improve the LOD to 1.5 μM with very low applied potential of 0 V vs Ag. The detection of glucose in deproteinized human serum samples was possible with negligible interference of oxidizable blood components. The results were verified by a commercial glucometer and standard kit for photometric detection of glucose. Strong correlation between the methods was confirmed; the determination of glucose in serum was performed with a relative standard deviation of 4 %. The developed sensor exhibits a great potential for rapid and sensitive non-enzymatic glucose detection in clinical applications.
Návaznosti
ED1.1.00/02.0068, projekt VaVNázev: CEITEC - central european institute of technology
VytisknoutZobrazeno: 30. 5. 2024 14:51