2016
A comparison of electrochemically pre-treated and spark-platinized carbon fiber microelectrode. Measurement of 8-oxo-7,8-dihydro-2 '-deoxyguanosine in human urine and plasma
BARTOŠOVÁ, Zdenka, Daniel RIMAN, Vladimír HALOUZKA, Jitka VOSTÁLOVÁ, Vilím ŠIMÁNEK et. al.Základní údaje
Originální název
A comparison of electrochemically pre-treated and spark-platinized carbon fiber microelectrode. Measurement of 8-oxo-7,8-dihydro-2 '-deoxyguanosine in human urine and plasma
Název česky
Srovnání elektrochemicky upravené a jiskrovým výbojem platinizované mikroelektrody z uhlíkového vlákna. Měření 8-oxo-7,8-dihydro-2 '-deoxyguanosinu v moči a ktrevní plasmě.
Autoři
BARTOŠOVÁ, Zdenka (203 Česká republika), Daniel RIMAN (203 Česká republika), Vladimír HALOUZKA (203 Česká republika), Jitka VOSTÁLOVÁ (203 Česká republika), Vilím ŠIMÁNEK (203 Česká republika), Jan HRBÁČ (203 Česká republika, garant, domácí) a David JIROVSKÝ (203 Česká republika)
Vydání
Analytica Chimica Acta, Amsterdam, Elsevier Science publishers, 2016, 0003-2670
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10405 Electrochemistry
Stát vydavatele
Nizozemské království
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 4.950
Kód RIV
RIV/00216224:14310/16:00091051
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000382249600005
Klíčová slova anglicky
Carbon fiber microelectrode; Platinization; Spark discharge; 8-oxo-7_8-dihydro-2 '-deoxyguanosine; Amperometric detection; Liquid chromatography
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 28. 3. 2017 17:10, Ing. Andrea Mikešková
Anotace
V originále
A novel method of carbon fiber microelectrode activation using spark discharge was demonstrated and compared to conventional electrochemical pretreatment by potential cycling. The spark discharge was performed at 800 V between the microelectrode connected to positive pole of the power supply and platinum counter electrode. Spark discharge led both to trimming of the fiber tip into conical shape and to the modification of carbon fiber microelectrode with platinum, as proven by scanning electron microscopy and electron dispersive X-ray spectroscopy. After the characterization of electrochemical properties using ferricyanide voltammetry, the activated electrodes were used for electrochemical analysis of 8-oxo-7,8-dihydro-2'-deoxyguanosine, an oxidative stress marker. Subnanomolar detection limits (0.55 nmol L-1) in high-performance liquid chromatography were achieved for spark platinized electrodes incorporated into the flow detection cell. (C) 2016 Elsevier B.V. All rights reserved.