KOŠŤÁL, Michal, Zdeněk MATĚJ, František CVACHOVEC, Vojtěch RYPAR, Evžen LOSA, Jiří REJCHRT, Filip MRAVEC a Martin VEŠKRNA. Measurement and calculation of fast neutron and gamma spectra in well defined cores in LR-0 reactor. Applied Radiation and Isotopes. Elsevier, 2017, roč. 120, č. 1, s. 45-50. ISSN 0969-8043. Dostupné z: https://dx.doi.org/10.1016/j.apradiso.2016.11.004.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Measurement and calculation of fast neutron and gamma spectra in well defined cores in LR-0 reactor
Autoři KOŠŤÁL, Michal (203 Česká republika, garant), Zdeněk MATĚJ (203 Česká republika, domácí), František CVACHOVEC (203 Česká republika), Vojtěch RYPAR (203 Česká republika), Evžen LOSA (203 Česká republika), Jiří REJCHRT (203 Česká republika), Filip MRAVEC (203 Česká republika, domácí) a Martin VEŠKRNA (203 Česká republika, domácí).
Vydání Applied Radiation and Isotopes, Elsevier, 2017, 0969-8043.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10201 Computer sciences, information science, bioinformatics
Stát vydavatele Nizozemské království
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 1.123
Kód RIV RIV/00216224:14330/17:00095937
Organizační jednotka Fakulta informatiky
Doi http://dx.doi.org/10.1016/j.apradiso.2016.11.004
UT WoS 000392044700008
Klíčová slova anglicky LR-0; Neutron spectra; Cross section validation; Detector calibration; Zero power reactor utilization; Reactor Dosimetry
Změnil Změnil: RNDr. Pavel Šmerk, Ph.D., učo 3880. Změněno: 31. 5. 2022 17:32.
Anotace
A well-defined neutron spectrum is essential for many types of experimental topics and is also important for both calibration and testing of spectrometric and dosimetric detectors. Provided it is well described, such a spectrum can also be employed as a reference neutron field that is suitable for validating selected cross sections. The present paper aims to compare calculations and measurements of such a well-defined spectra in geometrically similar cores of the LR-0 reactor with fuel containing slightly different enrichments (2 %, 3.3% and 3.6 %). The common feature to all cores is a centrally located dry channel which can be used for the insertion of studied materials. The calculation of neutron and gamma spectra was realized with the MCNP6 code using ENDF/B-VII.0, JEFF-3.1, JENDL-3.3, ROSFOND-2010 and CENDL-3.1 nuclear data libraries. Only minor differences in neutron and gamma spectra were found in the comparison of the presented reactor cores with different fuel enrichments. One exception is the gamma spectrum in the higher energy region (above 8 MeV), where more pronounced variations could be observed.
VytisknoutZobrazeno: 26. 4. 2024 19:09