2016
Advanced MRI increases the diagnostic accuracy of recurrent glioblastoma: Single institution thresholds and validation of MR spectroscopy and diffusion weighted MR imaging
KAZDA, Tomáš, Martin BULIK, Petr POSPÍŠIL, Radek LAKOMÝ, Martin SMRČKA et. al.Základní údaje
Originální název
Advanced MRI increases the diagnostic accuracy of recurrent glioblastoma: Single institution thresholds and validation of MR spectroscopy and diffusion weighted MR imaging
Autoři
KAZDA, Tomáš (203 Česká republika, garant, domácí), Martin BULIK (203 Česká republika, domácí), Petr POSPÍŠIL (203 Česká republika, domácí), Radek LAKOMÝ (203 Česká republika, domácí), Martin SMRČKA (203 Česká republika, domácí), Pavel ŠLAMPA (203 Česká republika, domácí) a Radim JANČÁLEK (203 Česká republika, domácí)
Vydání
NeuroImage: Clinical, Oxford, Elsevier BV, 2016, 2213-1582
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
30000 3. Medical and Health Sciences
Stát vydavatele
Velká Británie a Severní Irsko
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 4.348
Kód RIV
RIV/00216224:14110/16:00092193
Organizační jednotka
Lékařská fakulta
UT WoS
000379504500035
Klíčová slova anglicky
Glioma; Recurrence; Imaging sensitivity; Spectroscopy; Apparent diffusion coefficient
Štítky
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 7. 12. 2016 13:04, Ing. Mgr. Věra Pospíšilíková
Anotace
V originále
The accurate identification of glioblastoma progression remains an unmet clinical need. The aimof this prospective single-institutional study is to determine and validate thresholds for the main metabolite concentrations obtained by MR spectroscopy (MRS) and the values of the apparent diffusion coefficient (ADC) to enable distinguishing tumor recurrence from pseudoprogression. Thirty-nine patients after the standard treatment of a glioblastoma underwent advanced imaging by MRS and ADC at the time of suspected recurrence -median time to progressionwas 6.7 months. The highest significant sensitivity and specificity to call the glioblastoma recurrence was observed for the total choline (tCho) to total N-acetylaspartate (tNAA) concentration ratiowith the threshold >= 1.3 (sensitivity 100.0% and specificity 94.7%). The ADCmean value higher than 1313 x 10(-6) mm(2)/s was associated with the pseudoprogression (sensitivity 98.3%, specificity 100.0%). The combination of MRS focused on the tCho/tNAA concentration ratio and the ADCmean value represents imaging methods applicable to early non-invasive differentiation between a glioblastoma recurrence and a pseudoprogression. However, the institutional definition and validation of thresholds for differential diagnostics is needed for the elimination of setup errors before implementation of these multimodal imaging techniques into clinical practice, as well as into clinical trials.