OKEME, Joseph O., Amandeep SAINI, Congqiao YANG, Jiping ZHU, Foppe SMEDES, Jana KLÁNOVÁ a Miriam L. DIAMOND. Calibration of polydimethylsiloxane and XAD-Pocket passive air samplers (PAS) for measuring gas- and particle-phase SVOCs. Atmospheric Environment. OXFORD (ENGLAND): Pergamon Press, 2016, roč. 143, OCTOBER, s. 202-208. ISSN 1352-2310. Dostupné z: https://dx.doi.org/10.1016/j.atmosenv.2016.08.023.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Calibration of polydimethylsiloxane and XAD-Pocket passive air samplers (PAS) for measuring gas- and particle-phase SVOCs
Autoři OKEME, Joseph O. (124 Kanada), Amandeep SAINI (124 Kanada), Congqiao YANG (124 Kanada), Jiping ZHU (124 Kanada), Foppe SMEDES (528 Nizozemské království, domácí), Jana KLÁNOVÁ (203 Česká republika, garant, domácí) a Miriam L. DIAMOND (124 Kanada).
Vydání Atmospheric Environment, OXFORD (ENGLAND), Pergamon Press, 2016, 1352-2310.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30304 Public and environmental health
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 3.629
Kód RIV RIV/00216224:14310/16:00093412
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1016/j.atmosenv.2016.08.023
UT WoS 000383932400018
Klíčová slova anglicky Passive sampling; Calibration; PDMS; XAD-Pocket; Phthalates; Flame-retardants
Štítky AKR, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Ing. Andrea Mikešková, učo 137293. Změněno: 30. 3. 2017 13:57.
Anotace
Polydimethylsiloxane (PDMS) has seen wide use as the stationary phase of gas chromatographic columns, a passive sampler in water, and recently as a personal exposure sampler, while styrene divinylbenzene copolymer (XAD) has been used extensively as a passive air sampler outdoors and indoors. We have introduced PDMS and XAD-Pocket as new indoor passive air samplers (PASs). The XAD-Pocket was designed to maximize the surface area-to-volume ratio of XAD and to minimize obstruction of air flow by the sampler housing. Methods were developed to expedite the use of these PASs for measuring phthalates, novel brominated flame-retardants (NFRs) and polybrominated diphenyl ethers (PBDEs) indoors. Sampling rates, Rs, (m(3) day(-1)), were measured during a 7-week calibration study. Variability within and between analyte groups was not statistically significant. As a result, generic values of 0.8 +/- 0.4 and 0.5 +/- 03 m(3) day(-1) dm(-2) are recommended for PDMS and XAD-Pocket for a 50-day deployment time, respectively. PDMS has a higher uptake rate and is easier to use than XAD-Pocket.