Redox-Pair-Defined Electrochemical Measurements: Biamperometric Setup for Elimination of Interferent Effects and for Sensing of Unstable Redox Systems

LACINA, Karel, Petr VANÝSEK, Petr BEDNÁŘ, Libuše TRNKOVÁ, Petr SKLÁDAL et. al.

Základní údaje

Originální název

Redox-Pair-Defined Electrochemical Measurements: Biamperometric Setup for Elimination of Interferent Effects and for Sensing of Unstable Redox Systems

Autoři

LACINA, Karel (203 Česká republika, garant, domácí), Petr VANÝSEK (203 Česká republika), Petr BEDNÁŘ (203 Česká republika, domácí), Libuše TRNKOVÁ (203 Česká republika, domácí) a Petr SKLÁDAL (203 Česká republika, domácí)

Vydání

ChemElectroChem, WEINHEIM, Wiley-V C H VERLAG GMBH, 2016, 2196-0216

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

10403 Physical chemistry

Stát vydavatele

Německo

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 4.136

Kód RIV

RIV/00216224:14740/16:00093649

Organizační jednotka

Středoevropský technologický institut

UT WoS

000380045400005

Klíčová slova česky

analytické metody; cyklická biamperometrie; elektrochemie; redoxní chemie; senzory

Klíčová slova anglicky

analytical methods; cyclic biamperometry; electrochemistry; redox chemistry; sensors

Štítky

Změněno: 23. 4. 2020 17:36, Mgr. Marie Šípková, DiS.

Anotace

V originále

Routine, large-scale monitoring, such as point-of-care systems, requires inexpensive and simple analytical schemes. An electroanalytical concept of biamperometry for such sensing systems has been overlooked due to widespread potentiostat-controlled experiments. Herein, biamperometry is introduced as a powerful tool. In particular, its ability to eliminate electrochemical interference is highlighted for a case study on employing [Fe(CN)(6)](4-)/[Fe(CN)(6)](3-), aminoferrocene (Fe2+)/[Ru(NH3)(6)](3+), and ascorbic acid as two redox pairs and one interfering compound, respectively. A specific signal 15 times higher than that of an unspecific signal is observed, even under unfavorable conditions such as a 1:5 molar ratio of specific-to-interfering redox entities. This system is successfully used to determine glucose in blood plasma. A further promising usage of biamperometry is illustrated by the study of an unstable redox system: the oxygen-dependent oxidation of [Ru(NH3)(6)](2+) in an aqueous environment.