J 2017

Using long-term air monitoring of semi-volatile organic compounds to evaluate the uncertainty in polyurethane-disk passive sampler-derived air concentrations

HOLT, Eva Mary Suzanne, Pernilla BOHLIN-NIZZETTO, Jana BORŮVKOVÁ, Tom HARNER, Jiří KALINA et. al.

Základní údaje

Originální název

Using long-term air monitoring of semi-volatile organic compounds to evaluate the uncertainty in polyurethane-disk passive sampler-derived air concentrations

Autoři

HOLT, Eva Mary Suzanne (36 Austrálie, domácí), Pernilla BOHLIN-NIZZETTO (752 Švédsko), Jana BORŮVKOVÁ (203 Česká republika, domácí), Tom HARNER (124 Kanada), Jiří KALINA (203 Česká republika, domácí), Lisa Emily MELYMUK (124 Kanada, domácí) a Jana KLÁNOVÁ (203 Česká republika, garant, domácí)

Vydání

Environmental Pollution, OXFORD, ELSEVIER SCI LTD, 2017, 0269-7491

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

30304 Public and environmental health

Stát vydavatele

Velká Británie a Severní Irsko

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 4.358

Kód RIV

RIV/00216224:14310/17:00096246

Organizační jednotka

Přírodovědecká fakulta

UT WoS

000390732300038

Klíčová slova anglicky

Passive sampling; Air monitoring; Data interpretation; Data comparability; Semi-volatile organic compounds (SVOCs)

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 12. 4. 2018 18:16, Ing. Nicole Zrilić

Anotace

V originále

Much effort has been made to standardise sampling procedures, laboratory analysis, data analysis, etc. for semi volatile organic contaminants (SVOCs). Yet there are some unresolved issues in regards to comparing measurements from one of the most commonly used passive samplers (PAS), the polyurethane foam (PUF) disk PAS (PUF-PAS), between monitoring networks or different studies. One such issue is that there is no universal means to derive a sampling rate (R-s) or to calculate air concentrations (Cab(air)) from PUF-PAS measurements for SVOCs. C-air was calculated from PUF-PAS measurements from a long-term monitoring program at a site in central Europe applying current understanding of passive sampling theory coupled with a consideration for the sampling of particle associated compounds. Cair were assessed against concurrent active air sampler (AAS) measurements. Use of "site-based/sampler-specific" variables: R-s, calculated using a site calibration, provided similar results for most gas-phase SVOCs to air concentrations derived using "default" values (commonly accepted R-s). Individual monthly PUF-PAS-derived air concentrations for the majority of the target compounds were significantly different (Wilcoxon signed-rank (WSR) test; p < 0.05) to AAS regardless of the input values (site/sampler based or default) used to calculate them. However, annual average PUF-PAS-derived air concentrations were within the same order of magnitude as AAS measurements except for the particle-phase polycyclic aromatic hydrocarbons (PAHs). Underestimation of PUF-derived air concentrations for particle-phase PAHs was attributed to a potential overestimation of the particle infiltration into the PUF-PAS chamber and underestimation of the particle bound fraction of PAHs.

Návaznosti

EHP-CZ02-OV-1-029-2015, interní kód MU
Název: DA VINCI – Zlepšení vizualizace, interpretace a srovnatelnosti dat o organických polutantech v dlouhodobých monitorovacích sítích
Investor: Ministerstvo životního prostředí ČR, DA VINCI – Zlepšení vizualizace, interpretace a srovnatelnosti dat o organických polutantech v dlouhodobých monitorovacích sítích
LM2015037, projekt VaV
Název: ACTRIS – účast České republiky (Akronym: ACTRIS-CZ)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, ACTRIS-CZ - Aerosol, Clouds and Trace Gases Research Infrastructure Network
LM2015051, projekt VaV
Název: Centrum pro výzkum toxických látek v prostředí (Akronym: RECETOX RI)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Výzkumná infrastruktura RECETOX
LO1214, projekt VaV
Název: Centrum pro výzkum toxických látek v prostředí (Akronym: RECETOX)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Centrum pro výzkum toxických látek v prostředí