J 2016

The robust bio-immobilization based on pulsed plasma polymerization of cyclopropylamine and glutaraldehyde coupling chemistry

MANAKHOV, Anton, Ekaterina MAKHNEVA, Petr SKLÁDAL, David NEČAS, Jan CECHAL et. al.

Základní údaje

Originální název

The robust bio-immobilization based on pulsed plasma polymerization of cyclopropylamine and glutaraldehyde coupling chemistry

Autoři

MANAKHOV, Anton (643 Rusko, domácí), Ekaterina MAKHNEVA (643 Rusko, domácí), Petr SKLÁDAL (203 Česká republika, domácí), David NEČAS (203 Česká republika, domácí), Jan CECHAL (203 Česká republika), Lukas KALINA (203 Česká republika), Marek ELIÁŠ (203 Česká republika, domácí) a Lenka ZAJÍČKOVÁ (203 Česká republika, garant, domácí)

Vydání

Applied Surface Science, AMSTERDAM, Elsevier Science BV, 2016, 0169-4332

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

10403 Physical chemistry

Stát vydavatele

Nizozemské království

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 3.387

Kód RIV

RIV/00216224:14740/16:00093848

Organizační jednotka

Středoevropský technologický institut

UT WoS

000366591200005

Klíčová slova anglicky

Amine coating; Sensors; Bio-immobilization; Plasma polymerization; Cyclopropylamine; XPS; QCM

Štítky

Změněno: 19. 9. 2017 04:54, doc. Mgr. Lenka Zajíčková, Ph.D.

Anotace

V originále

The performance of immunosensing devices crucially depends on the methodology of antibody or antigen immobilization on the sensor surface. Hence, the stable intermediate layers capable of specific and reproducible binding of antibodies are required. Herein, we introduce the amine rich (NHx concentration of 6 at.%) layers prepared by pulsed plasma polymerization of cyclopropylamine (CPA) for functionalization of the quartz crystal microbalance (QCM) surface by the antibody specific to human serum albumin. In these layers the amine groups serve as anchor for the antibody binding. The sensitivity of QCM sensors prepared in this way surpasses the one for the previously reported sensors functionalized by the thiolbased self-assembled monolayers by the factor of 2. Our results thus show that CPA plasma polymers have a significant potential for further development of the active layers for biosensing applications. (C) 2015 Elsevier B.V. All rights reserved.