MAKHNEVA, Ekaterina, Anton MANAKHOV, Petr SKLÁDAL a Lenka ZAJÍČKOVÁ. Development of effective QCM biosensors by cyclopropylamine plasma polymerization and antibody immobilization using cross-linking reactions. SURFACE & COATINGS TECHNOLOGY. LAUSANNE: ELSEVIER SCIENCE SA, 2016, roč. 290, March, s. 116-123. ISSN 0257-8972. Dostupné z: https://dx.doi.org/10.1016/j.surfcoat.2015.09.035.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Development of effective QCM biosensors by cyclopropylamine plasma polymerization and antibody immobilization using cross-linking reactions
Autoři MAKHNEVA, Ekaterina (643 Rusko, domácí), Anton MANAKHOV (643 Rusko, domácí), Petr SKLÁDAL (203 Česká republika, domácí) a Lenka ZAJÍČKOVÁ (203 Česká republika, garant, domácí).
Vydání SURFACE & COATINGS TECHNOLOGY, LAUSANNE, ELSEVIER SCIENCE SA, 2016, 0257-8972.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10302 Condensed matter physics
Stát vydavatele Švýcarsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.589
Kód RIV RIV/00216224:14740/16:00093849
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1016/j.surfcoat.2015.09.035
UT WoS 000374370600019
Klíčová slova anglicky Plasma polymerization; Cyclopropylamine; Stable amine-rich films; Quartz crystal microbalance; Immunosensor; Label-free detection
Štítky rivok
Změnil Změnila: doc. Mgr. Lenka Zajíčková, Ph.D., učo 1414. Změněno: 19. 9. 2017 04:53.
Anotace
Biosensors have been extensively developed and applied for biomedical and environmental studies. Although there are many different types of biosensing techniques, immobilization of the biorecognition biomolecules onto the sensor surface is always required. Cyclopropylamine pulsed plastha polymerization in radio frequency (RF) capacitive discharges was employed to deposit amine thin films on the gold electrode of quartz crystal microbalance (QCM) biosensors and the monoclonal antibody AL-01, specific to human serum albumin (HSA), was immobilized onto the plasma polymer surface. Two different amine plasma polymers were studied. They had a similar amount of primary amine groups, 13-1.5 at.%, as determined by chemical derivatization but their stability in water was different. The 1st type, deposited at the floating potential and 120 Pa, exhibited 16% thickness loss after 24 h in water whereas the 2nd type deposited at RF electrode and 50 Pa was completely stable (2% thickness loss). Glutaraldehyde (GA) coupling of AL-01 was employed for both types of the amine films and the performance of QCM immunosensors was evaluated by the immunoassay flow test A high-stability of the frequency signal was obtained in both the cases but the 2nd type of the film provided low response to HSA. It was explained by its highly cross-linked structure and steric hindrance of active sites. Three different antibody immobilization methods were explored for the 1st type of the film. Stable baseline, selective and high response were recorded for GA and sulfo-SMCC methods. The results confirmed that the presented methodologies for the grafting of biomolecules on the gold are highly efficient and very promising for future use in biosensing. (C) 2015 Elsevier B.V. All rights reserved.
Návaznosti
ED1.1.00/02.0068, projekt VaVNázev: CEITEC - central european institute of technology
VytisknoutZobrazeno: 13. 5. 2024 03:02