VEGSO, Karol, Matej JERGEL, Peter SIFFALOVIC, Eva MAJKOVA, Dusan KORYTAR, Zdenko ZAPRAZNY, Petr MIKULÍK a Patrik VAGOVIC. Towards high-flux X-ray beam compressing channel-cut monochromators. Journal of Applied Crystallography. Chester: INT UNION CRYSTALLOGRAPHY, 2016, roč. 49, December, s. 1885-1892. ISSN 1600-5767. Dostupné z: https://dx.doi.org/10.1107/S1600576716013376.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Towards high-flux X-ray beam compressing channel-cut monochromators
Autoři VEGSO, Karol (703 Slovensko), Matej JERGEL (703 Slovensko), Peter SIFFALOVIC (703 Slovensko), Eva MAJKOVA (703 Slovensko), Dusan KORYTAR (703 Slovensko), Zdenko ZAPRAZNY (703 Slovensko), Petr MIKULÍK (203 Česká republika, garant, domácí) a Patrik VAGOVIC (276 Německo).
Vydání Journal of Applied Crystallography, Chester, INT UNION CRYSTALLOGRAPHY, 2016, 1600-5767.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10403 Physical chemistry
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.614
Kód RIV RIV/00216224:14740/16:00093863
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1107/S1600576716013376
UT WoS 000391195900004
Klíčová slova anglicky X-ray beam compressing channel-cut monochromators; single-point diamond technology; X-ray diffraction; small-angle X-ray scattering; grazing-incidence small-angle X-ray scattering; SAXS/GISAXS
Štítky rivok
Změnil Změnila: Mgr. Eva Špillingová, učo 110713. Změněno: 10. 3. 2017 08:50.
Anotace
The issue of a high-flux X-ray beam compressing channel-cut monochromator for applications in X-ray metrology is addressed. A Ge(111) compressor with compression ratio 20.3 was designed on the principle of a combination of symmetric and highly asymmetric diffractions. A pilot application of the single-point diamond technology (SPDT) to finish active surfaces of X-ray optics was tested, providing 50% flux enhancement as compared to a Ge(220) counterpart prepared by traditional surface treatment. This is much more than the theoretical 22% forecast and shows the potential of SPDT for preparation of high-flux X-ray compressors with a high compression ratio, where highly asymmetric diffraction with a very low exit angle is inevitable. The implications for efficient collection of X-rays from microfocus X-ray sources are discussed. A comparison of Ge compressors with Ge parallel channel-cut monochromators combined with a 50 mm slit shows the several times higher flux of the former, making them applicable in X-ray diffraction experiments at medium resolution. Furthermore, the Ge(111) compressor was tested as a collimator in high-resolution grazing-incidence small-angle X-ray scattering (GISAXS) measurements of surface gratings, providing experimental resolution close to 400 nm. This is similar to 100 nm smaller than that achieved with the Ge(220) compressor but still approximately twice that of commercial SAXS/GISAXS laboratory setups.
VytisknoutZobrazeno: 26. 8. 2024 02:59