LATTA, Peter, Zenon STARCUK, Marco L. H. GRUWEL, Michael H. WEBER a Boguslaw TOMANEK. K-space trajectory mapping and its application for ultrashort Echo time imaging. MAGNETIC RESONANCE IMAGING. NEW YORK: ELSEVIER SCIENCE INC, 2017, roč. 36, February, s. 68-76. ISSN 0730-725X. Dostupné z: https://dx.doi.org/10.1016/j.mri.2016.10.012.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název K-space trajectory mapping and its application for ultrashort Echo time imaging
Autoři LATTA, Peter (703 Slovensko, garant, domácí), Zenon STARCUK (203 Česká republika), Marco L. H. GRUWEL (36 Austrálie), Michael H. WEBER (124 Kanada) a Boguslaw TOMANEK (616 Polsko, domácí).
Vydání MAGNETIC RESONANCE IMAGING, NEW YORK, ELSEVIER SCIENCE INC, 2017, 0730-725X.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 20600 2.6 Medical engineering
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.564
Kód RIV RIV/00216224:14740/17:00094674
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1016/j.mri.2016.10.012
UT WoS 000393536100010
Klíčová slova anglicky Gradient imperfections; K-space deviation; Trajectory estimation; Ultrashort echo time (UTE)
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Pavla Foltynová, Ph.D., učo 106624. Změněno: 23. 2. 2018 12:50.
Anotace
MR images are affected by system delays and gradient field imperfections which induce discrepancies between prescribed and actual k-space trajectories. This could be even more critical for non-Cartesian data acquisitions where even a small deviation from the assumed k-space trajectory results in severe image degradation and artifacts. Knowledge of the actual k-space trajectories is therefore crucial and can be incorporated in the reconstruction of high quality non-Cartesian images. A novel MR method for the calibration of actual gradient waveforms was developed using a combination of phase encoding increments and subsequent detection of the exact time point at which the corresponding trajectory is crossing the k-space origin. The measured sets of points were fitted to a parametrical model to calculate the complete actual acquisition trajectory. Measurements performed on phantoms and volunteers, positioned both in- and off-isocenter of the magnet, clearly demonstrate the improvement in reconstructed ultrashort echo time (UTE) images, when information from calibration of k-space sampling trajectories is employed in the MR image reconstruction procedure. The unique feature of the proposed method is its robustness and simple experimental setup, making it suitable for quick acquisition trajectory calibration procedures e.g. for non-Cartesian radial fast imaging. (C) 2016 Elsevier Inc. All rights reserved.
Návaznosti
GA15-12607S, projekt VaVNázev: Návrh a optimalizace pulzních sekvenci s ultrakrátkým echо-časem pro spolehlivou detekci obsahu myelinu v lidském mozku pomocí MR zobrazování.
Investor: Grantová agentura ČR, Návrh a optimalizace pulzních sekvenci s ultrakrátkým echо-časem pro spolehlivou detekci obsahu myelinu v lidském mozku pomocí MR zobrazování