D 2016

Neutron/gamma-ray discrimination through measures of fit

AMIRI, Moslem, Václav PŘENOSIL and František CVACHOVEC

Basic information

Original name

Neutron/gamma-ray discrimination through measures of fit

Name in Czech

Separace neutronů a fama záření metodou FITt

Authors

AMIRI, Moslem (364 Islamic Republic of Iran, guarantor, belonging to the institution), Václav PŘENOSIL (203 Czech Republic, belonging to the institution) and František CVACHOVEC (203 Czech Republic, belonging to the institution)

Edition

Lisbon, 2015 4th International Conference on Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA), p. 1-5, 5 pp. 2016

Publisher

IEEE

Other information

Language

English

Type of outcome

Stať ve sborníku

Field of Study

20206 Computer hardware and architecture

Confidentiality degree

není předmětem státního či obchodního tajemství

Publication form

electronic version available online

RIV identification code

RIV/00216224:14330/16:00087671

Organization unit

Faculty of Informatics

ISBN

978-1-4799-9918-7

UT WoS

000398710600070

Keywords (in Czech)

organická scintilátor, čítač; statistický test; metoda FIT; neutronová spektroskopie

Keywords in English

organic scintillator; counter; statistical test; measures of fit; neutron spectroscopy

Tags

International impact, Reviewed
Změněno: 13/5/2020 20:55, RNDr. Pavel Šmerk, Ph.D.

Abstract

V originále

Statistical tests and their underlying measures of fit can be utilized to separate neutron/gamma-ray pulses in a mixed radiation field. In this article, first the application of a sample statistical test is explained. Fit measurement-based methods require true pulse shapes to be used as reference for discrimination. This requirement makes practical implementation of these methods difficult; typically another discrimination approach should be employed to capture samples of neutrons and gamma-rays before running the fit-based technique. In this article, we also propose a technique to eliminate this requirement. These approaches are applied to several sets of mixed neutron and gamma-ray pulses obtained through different digitizers using stilbene scintillator in order to analyze them and measure their discrimination quality.

In Czech

Statistické testy a jejich základní postupy mohou být použity pro separaci neutronů/gama záření ve smíšeném radiačním poli. V tomto článku je popsána první aplikace vzorku statistického testu. FIT metoda měření vyžaduje skutečné tvary impulsů, které mají být použity jako referenční pro vlastní diskriminaci. Tento požadavek metody je pro praktickou aplikaci problematický - obvykle by měla být použita jiný postup diskriminace pro zachycování vzorků neutronů a gama záření před aplikací metody FIT. V tomto článku se také navrhujeme techniku k odstranění tohoto požadavku. Tyto přístupy jsou aplikovány na několika sadách vzorků smíšeného pole neutronů a gama záření získaných několika typy digitizérů s použití scintiátoru stilbene pro získání představy o jejich podílu na kvalitě diskriminace.

Links

TA01011383, research and development project
Name: Digitální spektrometrický systém jaderného záření

Files attached