2017
FROM POLAROGRAPHY TO ELIMINATION VOLTAMMETRY
TRNKOVÁ, LibušeZákladní údaje
Originální název
FROM POLAROGRAPHY TO ELIMINATION VOLTAMMETRY
Autoři
TRNKOVÁ, Libuše (203 Česká republika, garant, domácí)
Vydání
1. vyd. Brno, XVII. Workshop of Physical Chemists and Electrochemists, od s. 23-24, 2 s. 2017
Nakladatel
Masarykova univerzita
Další údaje
Jazyk
angličtina
Typ výsledku
Stať ve sborníku
Obor
10403 Physical chemistry
Stát vydavatele
Česká republika
Utajení
není předmětem státního či obchodního tajemství
Forma vydání
elektronická verze "online"
Kód RIV
RIV/00216224:14310/17:00096905
Organizační jednotka
Přírodovědecká fakulta
ISBN
978-80-210-8580-0
Klíčová slova anglicky
elimination polarography; elimination voltammetry; adsorbed electroactive species; oligodeoxynucleotides
Změněno: 21. 3. 2018 22:18, Ing. Nicole Zrilić
Anotace
V originále
Thirty years ago the theory of elimination polarography (EP) and elimination voltammetry with linear scan (EVLS) was firstly published and experimentally verified [1-6]. The elimination procedure applied in both polarography as well as voltammetry can be considered as a mathematical model of the transformation of current-potential curves capable of eliminating some selected current components, while conserving others by means of elimination functions. While the elimination functions in EP use the differential dependence of a current component on time, the EVLS works on the basis of the different dependence of current components (diffusion, charging and kinetic) on the scan rate. Thereafter, the chosen EVLS function needs two or three voltammetric (LSV or CV) curves measured at different scan rates only. Due to longer time and experimental demands of elimination polarography, EVLS has been achieving greater development and usage during last decade. To this date it has found applications not only in electroanalysis, but also in studying electrode processes of inorganic and organic electroactive substances at mercury, silver and/or graphite electrodes [7-35]. For fully adsorbed electroactive species the function eliminating charging and kinetic current components, and conserving the diffusion current component, yields the specific, sensitive and well developed peak-counterpeak (p-cp) signal [7,8,16]. This signal, usually 10-20 times higher than corresponding measured voltammetric peak, is successfully employed in the analysis of nucleic acids and short homo- or hetero-deoxyoligonucleotides (ODNs) containing adenine and cytosine [10,15,17,19,21,22,33,34]. Moreover, it has been shown that the EVLS in combination with adsorptive stripping procedure is a promising tool for achieving very good resolution of electrode processes, for qualitative and quantitative analysis of ODNs and their components, as well as for the identification of ODN structures [10,15,17,19,21,22,33,34].