2017
Fluorescence measurement of atomic oxygen concentration in a dielectric barrier discharge
DVOŘÁK, Pavel, Martina MRKVIČKOVÁ, Adam OBRUSNÍK, Kratzer JAN, Dědina JIŘÍ et. al.Základní údaje
Originální název
Fluorescence measurement of atomic oxygen concentration in a dielectric barrier discharge
Název česky
Fluorescenční měření koncentrace atomárního kyslíku v dielektrickém bariérovém výboji
Autoři
DVOŘÁK, Pavel (203 Česká republika, garant, domácí), Martina MRKVIČKOVÁ (203 Česká republika, domácí), Adam OBRUSNÍK (203 Česká republika, domácí), Kratzer JAN (203 Česká republika), Dědina JIŘÍ (203 Česká republika) a Vojtěch PROCHÁZKA (203 Česká republika, domácí)
Vydání
Plasma Sources Science and Technology, Bristol, England, IOP PUBLISHING LTD, 2017, 0963-0252
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10305 Fluids and plasma physics
Stát vydavatele
Velká Británie a Severní Irsko
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 3.939
Kód RIV
RIV/00216224:14310/17:00094851
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000403309700002
Klíčová slova česky
Laserem indukovaná fluorescence; TALIF; atomární kyslík; O; dielektrický bariérový výboj
Klíčová slova anglicky
Laser induced fluorescence; TALIF; atomic oxygen; O; dielectric barrier discharges
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 3. 4. 2018 16:19, Ing. Nicole Zrilić
V originále
Concentration of atomic oxygen was measured in a volume dielectric barrier discharge (DBD) ignited in mixtures of Ar + O2 (+ H2) at atmospheric pressure. Two-photon absorption laser induced fluorescence (TALIF) of atomic oxygen was used and this method was calibrated by TALIF of Xe in a mixture of argon and a trace of xenon. The calibration was performed at atmospheric pressure and it was shown that quenching by three-body collisions has negligible effect on the life time of excited Xe atoms. The concentration of atomic oxygen in the DBD was around 10^{21} m-3 and it was stable during the whole discharge period. The concentration did not depend much on the electric power delivered to the discharge provided that the power was sufficiently high so that the visible discharge filled the whole reactor volume. Both the addition of hydrogen or replacing of argon by helium led to a significant decrease of atomic oxygen concentration. The TALIF measurements of O concentration levels in the DBD plasma performed in this work are made use of e.g. in the field analytical chemistry. The results contribute to understanding the processes of analyte hydride preconcentration and subsequent atomization in the field of trace element analysis where DBD plasma atomizers are employed.
Česky
Koncentrace atomárního kyslíku byla metodou TALIF měřena v dielektrickém bariérovém výboji iniciovaném za atmosférického tlaku ve směsích Ar + O2 (+ H2) a počítána modelem.
Návaznosti
CZ.1.05/2.1.00/03.0086, interní kód MU |
| ||
GA13-24635S, projekt VaV |
| ||
GA17-04329S, projekt VaV |
| ||
LO1411, projekt VaV |
| ||
7AMB14SK204, projekt VaV |
|