J 2017

LC coupled to ESI, MALDI and ICP MS - A multiple hyphenation for metalloproteomic studies

COUFALÍKOVÁ, Kateřina, Iva BENEŠOVÁ, Tomáš VACULOVIČ, Viktor KANICKÝ, Jan PREISLER et. al.

Základní údaje

Originální název

LC coupled to ESI, MALDI and ICP MS - A multiple hyphenation for metalloproteomic studies

Autoři

COUFALÍKOVÁ, Kateřina (203 Česká republika, domácí), Iva BENEŠOVÁ (203 Česká republika, domácí), Tomáš VACULOVIČ (203 Česká republika, domácí), Viktor KANICKÝ (203 Česká republika, domácí) a Jan PREISLER (203 Česká republika, garant, domácí)

Vydání

Analytica Chimica Acta, Amsterdam, Elsevier Science BV, 2017, 0003-2670

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

10406 Analytical chemistry

Stát vydavatele

Nizozemské království

Utajení

není předmětem státního či obchodního tajemství

Impakt faktor

Impact factor: 5.123

Kód RIV

RIV/00216224:14310/17:00094859

Organizační jednotka

Přírodovědecká fakulta

UT WoS

000398436800006

Klíčová slova anglicky

Matrix-assisted laser desorption/ionization; mass spectrometry; Inductively coupled plasma mass; spectrometry; Electrospray ionization mass spectrometry; Liquid chromatography; Metallothionein isoforms; Metal complexes

Štítky

Změněno: 6. 4. 2018 11:38, Ing. Nicole Zrilić

Anotace

V originále

A new multiple detection arrangement for liquid chromatography (LC) that supplements conventional electrospray ionization (ESI) mass spectrometry (MS) detection with two complementary detection techniques, matrix-assisted laser desorption/ionization (MALDI) MS and substrate-assisted laser desorption inductively coupled plasma (SALD ICP) MS has been developed. The combination of the molecular and elemental detectors in a single separation run is accomplished by utilizing a commercial MALDI target made of conductive plastic. The proposed platform provides a number of benefits in today's metalloproteomic applications, which are demonstrated by analysis of a metallothionein mixture. To maintain metallothionein complexes, separation is carried out at a neutral pH. The effluent is split; a major portion is directed to ESI MS while the remaining 1.8% fraction is deposited onto a plastic MALDI target. Dried droplets are overlaid with MALDI matrix and analysed consecutively by MALDI MS and SALD ICP MS. In the ESI MS spectra, the MT isoform complexes with metals and their stoichiometry are determined; the apoforms are revealed in the MALDI MS spectra. Quantitative determination of metallothionein isoforms is performed via determination of metals in the complexes of the individual protein isoforms using SALD ICP MS. (C) 2017 Elsevier B.V. All rights reserved.

Návaznosti

GA15-05387S, projekt VaV
Název: Laserově desorpční hmotnostní spektrometrie pro analýzu molekul a nanočástic
Investor: Grantová agentura ČR, Laserově desorpční hmotnostní spektrometrie pro analýzu molekul a nanočástic
LQ1601, projekt VaV
Název: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020