J 2017

Quantification of elemental mapping of heterogeneous geological sample by laser ablation inductively coupled plasma mass spectrometry

VACULOVIČ, Tomáš, Karel BREITER, Zuzana KORBELOVÁ, Natálie VENCLOVÁ, Kateřina TOMKOVÁ et. al.

Základní údaje

Originální název

Quantification of elemental mapping of heterogeneous geological sample by laser ablation inductively coupled plasma mass spectrometry

Autoři

VACULOVIČ, Tomáš (203 Česká republika, garant, domácí), Karel BREITER (203 Česká republika), Zuzana KORBELOVÁ (203 Česká republika), Natálie VENCLOVÁ (203 Česká republika), Kateřina TOMKOVÁ (203 Česká republika), Šárka JONÁŠOVÁ (203 Česká republika) a Viktor KANICKÝ (203 Česká republika, domácí)

Vydání

Microchemical Journal, Amsterdam, Elsevier Science, 2017, 0026-265X

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

10406 Analytical chemistry

Stát vydavatele

Česká republika

Utajení

není předmětem státního či obchodního tajemství

Impakt faktor

Impact factor: 2.746

Kód RIV

RIV/00216224:14310/17:00094928

Organizační jednotka

Přírodovědecká fakulta

UT WoS

000403121900029

Klíčová slova anglicky

LA-ICP-MS; quantification; imaging; archaeological samples; geological samples

Štítky

Změněno: 11. 4. 2018 10:36, Ing. Nicole Zrilić

Anotace

V originále

Quantification procedures based on the external calibration with total sum content standardization (ECTSCS) and the external calibration with internal standardization (ECIS) were compared in the analysis of glass materials by laser ablation inductively coupled plasma spectrometry (LA-ICP-MS) with a 213 nm Nd:YAG laser ablation device and a quadrupole mass spectrometer. Silicon was used as the internal reference element for ECIS. Applicability of these approaches was statistically tested using both homogeneous and inhomogeneous samples. The former type was represented by the standard reference material NIST 612 and an ancient glass bead (Early Bronze Age), while the latter was a mediaeval glass artefact (8th - 9th century). Homogeneity of samples was examined by EMP analysis. Identical results were obtained by both calibration methods for homogeneous samples, while underestimated contents resulted from quantification with ECIS method in comparison to EMP analyses of the same target area of inhomogeneous glass. Finally, elemental maps of zonal muscovite grain were recorded and quantified using ECTSCS method and verified by EMP analysis.

Návaznosti

GA14-13600S, projekt VaV
Název: Otevřené procesy v granitoidech z pohledu zonality minerálů a horninových textur
Investor: Grantová agentura ČR, Otevřené procesy v granitoidech z pohledu zonality minerálů a horninových textur
LQ1601, projekt VaV
Název: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020