HLAVÁČEK, Antonín, Miroslav PETEREK, Zdeněk FARKA, Matthias J. MICKERT, Leonhard PRECHTL, Dietmar KNOPP a Hans H. GORRIS. Rapid single-step upconversion-linked immunosorbent assay for diclofenac. Microchimica Acta. Vienna: Springer, 2017, roč. 184, č. 10, s. 4159-4165. ISSN 0026-3672. Dostupné z: https://dx.doi.org/10.1007/s00604-017-2456-0.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Rapid single-step upconversion-linked immunosorbent assay for diclofenac
Autoři HLAVÁČEK, Antonín (203 Česká republika, domácí), Miroslav PETEREK (203 Česká republika, domácí), Zdeněk FARKA (203 Česká republika, domácí), Matthias J. MICKERT (276 Německo), Leonhard PRECHTL (276 Německo), Dietmar KNOPP (276 Německo) a Hans H. GORRIS (276 Německo, garant).
Vydání Microchimica Acta, Vienna, Springer, 2017, 0026-3672.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Rakousko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 5.705
Kód RIV RIV/00216224:14740/17:00097559
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1007/s00604-017-2456-0
UT WoS 000410517400062
Klíčová slova anglicky Bioconjugation; Electrophoretic purification; Immunoassay; Luminescence; Pharmaceutical micropollutant; Photon-upconversion
Štítky CF CRYO, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Pavla Foltynová, Ph.D., učo 106624. Změněno: 15. 3. 2018 11:03.
Anotace
The non-steroidal anti-inflammatory drug and analgesic diclofenac is a common micropollutant in water. A direct competitive upconversion-linked immunosorbent assay (ULISA) for diclofenac has been developed that is based on a nanoparticulate tracer consisting of a NaYF4:Yb,Er core (diameter of ~90 nm, excitation and emission wavelenghts 980 and 535 nm, respectively) enclosed by a carboxylated silica shell and finally coated with diclofenac-conjugated bovine gamma-globulin. The proteinaceous coating prevents non-specific adsorption of the tracer to the microtiter plate and provides a structurally flexible linker for surface-exposed diclofenac to warrant efficient competition with free (analyte) diclofenac in real water samples. The tracer was purified by gel electrophoresis and lyophilized. Both processes have no adverse effects on the immunoassay. All assay components can be stored in a dry state without a cooling chain, and can be reactivated on demand. Hence, this ULISA is well suited for environmental monitoring in low-resource settings. The ULISA has a similar limit of detection (20 pg mL-1; equivalent to 70 pM) as the conventional ELISA, but the time for analysis is reduced to 70 min because no enzymatic amplification steps are involved.
Návaznosti
LD15023, projekt VaVNázev: Příprava diskrétních biokonjugátů photon-upconversion nanočástic
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Příprava diskrétních biokonjugátů photon-upconversion nanočástic
LM2015043, projekt VaVNázev: Česká infrastruktura pro integrativní strukturní biologii (Akronym: CIISB)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Czech Infrastructure for Integrative Structural Biology