Correlation between transversal and orthogonal maximal diameters of abdominal aortic aneurysms and alternative rupture risk predictors

NOVAK, K., S. POLZER, Tomáš KŘIVKA, Robert VLACHOVSKÝ, Robert STAFFA et. al.

Základní údaje

Originální název

Correlation between transversal and orthogonal maximal diameters of abdominal aortic aneurysms and alternative rupture risk predictors

Autoři

NOVAK, K. (203 Česká republika), S. POLZER (203 Česká republika), Tomáš KŘIVKA (203 Česká republika, garant, domácí), Robert VLACHOVSKÝ (203 Česká republika, domácí), Robert STAFFA (203 Česká republika, domácí), Luboš KUBÍČEK (203 Česká republika, domácí), L. LAMBERT (203 Česká republika) a J. BURSA (203 Česká republika)

Vydání

Computers in Biology and Medicine, OXFORD, PERGAMON-ELSEVIER SCIENCE LTD, 2017, 0010-4825

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

20601 Medical engineering

Stát vydavatele

Velká Británie a Severní Irsko

Utajení

není předmětem státního či obchodního tajemství

Impakt faktor

Impact factor: 2.115

Kód RIV

RIV/00216224:14110/17:00097641

Organizační jednotka

Lékařská fakulta

UT WoS

000399862200015

Klíčová slova anglicky

Abdominal aortic aneurysm; Correlation analysis; Maximal diameter; Peak wall stress; Peak wall rupture risk

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 18. 3. 2018 22:31, Soňa Böhmová

Anotace

V originále

Purpose: There is no standard for measuring maximal diameter (Dmax) of abdominal aortic aneurysm (AAA) from computer tomography (CT) images although differences between Dmax evaluated from transversal (axialDmax) or orthogonal (orthoDmax) planes can be large especially for angulated AAAs. Therefore we investigated their correlations with alternative rupture risk indicators as peak wall stress (PWS) and peak wall rupture risk (PWRR) to decide which Dmax is more relevant in AAA rupture risk assessment. Material and methods: The Dmax values were measured by a trained radiologist from 70 collected CT scans, and the corresponding PWS and PWRR were evaluated using Finite Element Analysis (FEA). The cohort was ordered according to the difference between axialDmax and orthoDmax (Da-o) quantifying the aneurysm angulation, and Spearman's correlation coefficients between PWS/PWRR orthoDmax/axialDmax were calculated. Results: The calculated correlations PWS/PWRR vs. orthoDmax were substantially higher for angulated AAAs (with Da-o >= 3mm). Under this limit, the correlations were almost the same for both Dmax values. Analysis of AAAs divided into two groups of angulated (n=38) and straight (n=32) cases revealed that both groups are similar in all parameters (orthoDmax, PWS, PWRR) with the exception of axialDmax (p=0.024). Conclusions: It was confirmed that orthoDmax is better correlated with the alternative rupture risk predictors PWS and PWRR for angulated AAA5 (DA-O >= 3mm) while there is no difference between orthoDmax and axialDmax for straight AAAs (DA-O<3mm). As angulated AAA5 represent a significant portion of cases it can be recommended to use orthoDmax as the only Dmax parameter for AAA rupture risk assessment.